Arabic
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Circulation 1989-Nov

Assessment of left ventricular functional preservation during isolated cardiac valve operations.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
يتم حفظ الارتباط في الحافظة
D H Harpole
J S Rankin
W G Wolfe
L R Smith
W G Young
F M Clements
R H Jones

الكلمات الدالة

نبذة مختصرة

To evaluate intraoperative changes in myocardial performance during valvular operations, ventricular functional measurements were obtained in 16 patients before and after elective cardiac valvular replacement. Six patients had mitral regurgitation, four had mitral stenosis, and six had calcific aortic stenosis; all patients underwent isolated mitral or aortic valve replacement. Cold potassium crystalloid cardioplegia, topical hypothermia, and low-flow systemic hypothermia were employed uniformly. Just before and 10 minutes after cardiopulmonary bypass was discontinued, left ventricular pressure and volume data were recorded at four to five different steady-state levels of filling produced by blood infusion or withdrawal from the aortic cannula (mean end-diastolic pressure range, 10-22 mm Hg; mean end-diastolic volume range, 120-168 ml). Portable first-pass radionuclide ventriculography and simultaneous micromanometry were used for construction of left ventricular pressure-volume loops from which stroke work and end-diastolic volume were calculated. Two-dimensional transesophageal echocardiograms also were recorded, and epicardial pacing maintained heart rate as constant as possible. As compared with prebypass measurements, echocardiographic left ventricular wall volume changed insignificantly after the valvular procedures (178-181 ml/m2, p greater than 0.5). The stroke work-end-diastolic volume relationship before and after operation was highly linear in all studies (mean = 0.97). The slope and x intercept of this relationship did not change significantly after operation, indicating a stable level of left ventricular function (from 12.7 x 10(4) to 10.0 x 10(4) ergs/ml and from 67 to 57 ml, respectively; p greater than 0.3).(ABSTRACT TRUNCATED AT 250 WORDS)

انضم إلى صفحتنا على الفيسبوك

قاعدة بيانات الأعشاب الطبية الأكثر اكتمالا التي يدعمها العلم

  • يعمل في 55 لغة
  • العلاجات العشبية مدعومة بالعلم
  • التعرف على الأعشاب بالصورة
  • خريطة GPS تفاعلية - ضع علامة على الأعشاب في الموقع (قريبًا)
  • اقرأ المنشورات العلمية المتعلقة ببحثك
  • البحث عن الأعشاب الطبية من آثارها
  • نظّم اهتماماتك وابقَ على اطلاع دائم بأبحاث الأخبار والتجارب السريرية وبراءات الاختراع

اكتب أحد الأعراض أو المرض واقرأ عن الأعشاب التي قد تساعد ، واكتب عشبًا واطلع على الأمراض والأعراض التي تستخدم ضدها.
* تستند جميع المعلومات إلى البحوث العلمية المنشورة

Google Play badgeApp Store badge