Arabic
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Forensic Science International 2003-Apr

Automated headspace solid-phase dynamic extraction for the determination of cannabinoids in hair samples.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
يتم حفظ الارتباط في الحافظة
Frank Musshoff
Dirk W Lachenmeier
Lars Kroener
Burkhard Madea

الكلمات الدالة

نبذة مختصرة

This article describes a fully automated procedure for detecting cannabinoids in human hair samples. The procedure uses alkaline hydrolysis and headspace solid-phase dynamic extraction (HS-SPDE), followed by on-coating derivatization and gas chromatography-mass spectrometry (GC-MS). SPDE is a further development of solid-phase microextraction (SPME), based on an inside needle capillary absorption trap. It uses a hollow needle with an internal coating of polydimethylsiloxane as extraction and pre-concentration medium. Ten mg of hair were washed with deionised water, petroleum ether and dichloromethane. After adding deuterated internal standards, the sample was hydrolyzed with sodium hydroxide and directly submitted to HS-SPDE. After absorption of analytes for an on-coating derivatization procedure, the SPDE-needle was directly placed into the headspace of a second vial containing N-methyl-N-trimethylsilyl-trifluoroacetamide before GC-MS analysis. The limit of detection was 0.14 ng/mg for Delta(9)-tetrahydrocannabinol, 0.09 ng/mg for cannabidiol, and 0.12ng/mg for cannabinol. Absolute recoveries were in the range of 0.6 to 8.4%. Linearity was verified over a range from 0.2 to 20 ng/mg, with coefficients of correlation between 0.998 and 0.999. Intra- and inter-day precision were determined at two different concentrations and resulted in ranges between 2.3 and 6.0% (intra-day) and 3.3 and 7.6% (inter-day). Compared with conventional methods of hair analysis, this automated HS-SPDE-GC-MS procedure is substantially faster. It is easy to perform without using solvents and with minimal sample quantities, and it yields the same sensitivity and reproducibility. Compared to SPME, we found a higher extraction rate, coupled with a faster automated operation and greater stability of the device.

انضم إلى صفحتنا على الفيسبوك

قاعدة بيانات الأعشاب الطبية الأكثر اكتمالا التي يدعمها العلم

  • يعمل في 55 لغة
  • العلاجات العشبية مدعومة بالعلم
  • التعرف على الأعشاب بالصورة
  • خريطة GPS تفاعلية - ضع علامة على الأعشاب في الموقع (قريبًا)
  • اقرأ المنشورات العلمية المتعلقة ببحثك
  • البحث عن الأعشاب الطبية من آثارها
  • نظّم اهتماماتك وابقَ على اطلاع دائم بأبحاث الأخبار والتجارب السريرية وبراءات الاختراع

اكتب أحد الأعراض أو المرض واقرأ عن الأعشاب التي قد تساعد ، واكتب عشبًا واطلع على الأمراض والأعراض التي تستخدم ضدها.
* تستند جميع المعلومات إلى البحوث العلمية المنشورة

Google Play badgeApp Store badge