Arabic
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Biosensors and Bioelectronics 2006-Jun

Detection of Escherichia coli O157:H7 with langasite pure shear horizontal surface acoustic wave sensors.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
يتم حفظ الارتباط في الحافظة
E Berkenpas
P Millard
M Pereira da Cunha

الكلمات الدالة

نبذة مختصرة

The toxigenic Escherichia coli O157:H7 bacterium has been connected with hemorrhagic colitis and hemolytic uremic syndrome, which may be characterized by diarrhea, kidney failure and death. On average, O157:H7 causes 73,000 illnesses, 2100 hospitalizations and 60 deaths annually in the United States alone. There is the need for sensors capable of rapidly detecting dangerous microbes in food and water supplies to limit the exposure of human and animal populations. Previous work by the authors used shear horizontal surface acoustic wave (SH SAW) devices fabricated on langasite (LGS) Euler angles (0 degrees, 22 degrees, 90 degrees) to successfully detect macromolecular protein assemblies. The devices also demonstrated favorable temperature stability, biocompatibility and low attenuation in liquid environments, suggesting their applicability to bacterial detection. In this paper, a biosensor test setup utilizing a small volume fluid injection system, stable temperature control and high frequency phase measurement was applied to validate LGS SH SAW biosensors for bacterial detection. The LGS SH SAW delay lines were fabricated and derivatized with a rabbit polyclonal IgG antibody, which selectively binds to E. coli O157:H7, in this case a non-toxigenic test strain. To quantify the effect of non-specific binding (negative control), an antibody directed against the trinitrophenyl hapten (TNP) was used as a binding layer. Test E. coli bacteria were cultured, fixed with formaldehyde, stained with cell-permeant nucleic acid stain, suspended in phosphate buffered saline and applied to the antibody-coated sensing surfaces. The biosensor transmission coefficient phase was monitored using a network analyzer. Phase responses of about 14 degrees were measured for the E. coli detection, as compared to 2 degrees due to non-specific anti-TNP binding. A 30:1 preference for E. coli binding to the anti-O157:H7 layer when compared to the anti-TNP layer was observed with fluorescence microscopy, thus confirming the selectivity of the antibody surface to E. coli.

انضم إلى صفحتنا على الفيسبوك

قاعدة بيانات الأعشاب الطبية الأكثر اكتمالا التي يدعمها العلم

  • يعمل في 55 لغة
  • العلاجات العشبية مدعومة بالعلم
  • التعرف على الأعشاب بالصورة
  • خريطة GPS تفاعلية - ضع علامة على الأعشاب في الموقع (قريبًا)
  • اقرأ المنشورات العلمية المتعلقة ببحثك
  • البحث عن الأعشاب الطبية من آثارها
  • نظّم اهتماماتك وابقَ على اطلاع دائم بأبحاث الأخبار والتجارب السريرية وبراءات الاختراع

اكتب أحد الأعراض أو المرض واقرأ عن الأعشاب التي قد تساعد ، واكتب عشبًا واطلع على الأمراض والأعراض التي تستخدم ضدها.
* تستند جميع المعلومات إلى البحوث العلمية المنشورة

Google Play badgeApp Store badge