Arabic
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Annals of Medicine and Surgery 2019-May

Development of a point-of-contact technique to measure adenosine triphosphate: A quality improvement study.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
يتم حفظ الارتباط في الحافظة
Janet Pierce
John Hiebert
Diane Mahoney
Qiuhua Shen
Jill Peltzer
Faith Rahman
Samantha Johnson
John Pierce

الكلمات الدالة

نبذة مختصرة

Patients with heart failure with preserved ejection fraction (HFpEF) experience fatigue due to impaired myocardial bioenergetics. Cardiomyocyte function depends on the delivery of adenosine triphosphate (ATP), yet there is no convenient bedside method to measure ATP. The purpose of this study was to develop a point-of-contact measurement of ATP that can be used in a clinical setting.In a laboratory setting, digital finger punctures were conducted using 5 μl and 10 μl of capillary blood placed into various amounts of water (H2O). After mixing the solution for 10 s, a Hygiena AquaSnapTM Free ATP probe was placed into the solution for 10 s for the detection of ATP. The probe was then placed into the Hygiena luminometer for 15 s, and a value in relative light units (RLU) was obtained.Test samples using 10 μl of blood diluted from 50 to 500 mls of H2O produced ATP readings of 10,000-7569 RLUs. Using 5 μl of blood in 375-900 ml of H2O decreased the ATP values to 6459-4189 RLUs. Dilutional volume sparing experiments were conducted with ATP standards to determine the concentration of ATP per RLUs.Patients with HFpEF have increased metabolic demand and impaired myocardial bioenergetics. Thus, identifying a method to measure ATP that is quick and accurate is imperative to accurately assess cellular energy production in this population. Point-of-contact measures, such as ATP, are needed for precision-guided treatment. Data from this study provides the first step toward developing evidence for health policies related to managing fatigue.

انضم إلى صفحتنا على الفيسبوك

قاعدة بيانات الأعشاب الطبية الأكثر اكتمالا التي يدعمها العلم

  • يعمل في 55 لغة
  • العلاجات العشبية مدعومة بالعلم
  • التعرف على الأعشاب بالصورة
  • خريطة GPS تفاعلية - ضع علامة على الأعشاب في الموقع (قريبًا)
  • اقرأ المنشورات العلمية المتعلقة ببحثك
  • البحث عن الأعشاب الطبية من آثارها
  • نظّم اهتماماتك وابقَ على اطلاع دائم بأبحاث الأخبار والتجارب السريرية وبراءات الاختراع

اكتب أحد الأعراض أو المرض واقرأ عن الأعشاب التي قد تساعد ، واكتب عشبًا واطلع على الأمراض والأعراض التي تستخدم ضدها.
* تستند جميع المعلومات إلى البحوث العلمية المنشورة

Google Play badgeApp Store badge