The European journal of surgery = Acta chirurgica 1997-Dec

Direct measurement of intra-abdominal pressure in various conditions.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
يتم حفظ الارتباط في الحافظة
A Shafik
A El-Sharkawy
W M Sharaf

الكلمات الدالة

نبذة مختصرة

OBJECTIVE

To standardise a direct method for measuring intra-abdominal pressure (IAP), to correlate the results with intrarectal pressure, and to compare the results in various conditions.

METHODS

Prospective open study.

METHODS

Teaching hospital, Egypt.

METHODS

34 Subjects in 4 groups: control (n = 11), hernia (n = 8; 6 umbilical and 2 incisional), mass (n = 7; 6 enlarged spleen and 1 carcinoma of sigmoid), and obese (n = 8; a mean of 40% above expected weight).

METHODS

Measurement of IAP with a Verres needle connected to a pressure transducer with the patient at rest, straining, supine, erect, and before and after anaesthesia. Intrarectal pressure was measured simultaneously.

METHODS

Reproducibility and correlation between the two measurements.

RESULTS

The hernia group had significantly lower IAP than controls both at rest and on straining (mean (SD) 2.7 (1.5) cm H2O compared with 7.0 (5.09) and 6.1 (2.7) compared with 20.5 (7.9), p < 0.01 in each case). Neither the mass nor the obese group differed from the controls at rest, but the pressure was higher on straining (31.2 (1.4) and 33.5 (2.07) cm H2O, respectively, compared with 21.9 (7.3), p < 0.05 in each case). There was a significant drop in IAP after anaesthesia in all groups, and no significant difference between intrarectal pressure and IAP in any group.

CONCLUSIONS

The method of measuring IAP is reproducible. Intrarectal pressure is similar to IAP and can therefore be used instead of it.

انضم إلى صفحتنا على الفيسبوك

قاعدة بيانات الأعشاب الطبية الأكثر اكتمالا التي يدعمها العلم

  • يعمل في 55 لغة
  • العلاجات العشبية مدعومة بالعلم
  • التعرف على الأعشاب بالصورة
  • خريطة GPS تفاعلية - ضع علامة على الأعشاب في الموقع (قريبًا)
  • اقرأ المنشورات العلمية المتعلقة ببحثك
  • البحث عن الأعشاب الطبية من آثارها
  • نظّم اهتماماتك وابقَ على اطلاع دائم بأبحاث الأخبار والتجارب السريرية وبراءات الاختراع

اكتب أحد الأعراض أو المرض واقرأ عن الأعشاب التي قد تساعد ، واكتب عشبًا واطلع على الأمراض والأعراض التي تستخدم ضدها.
* تستند جميع المعلومات إلى البحوث العلمية المنشورة

Google Play badgeApp Store badge