Arabic
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Gastrointestinal Endoscopy 2012-Apr

Hyoscine N-butylbromide does not improve polyp detection during colonoscopy: a double-blind, randomized, placebo-controlled, clinical trial.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
يتم حفظ الارتباط في الحافظة
Esther J de Brouwer
Maurits E Arbouw
Wil C van der Zwet
Margot A van Herwaarden
Michiel Ledeboer
Frank G Jansman
Frank ter Borg

الكلمات الدالة

نبذة مختصرة

BACKGROUND

Colonoscopy is used for the detection of neoplastic polyps, although a significant miss rate has been reported. Limited data suggest that the administration of the antispasmodic hyoscine N-butylbromide during colonoscopy improves polyp detection.

OBJECTIVE

To investigate whether the use of 20 mg hyoscine N-butylbromide intravenously during colonoscopy improves polyp detection or removal.

METHODS

A prospective, double-blind, placebo-controlled, randomized, clinical trial.

METHODS

Nonacademic teaching hospital.

METHODS

This study involved 674 patients who were routinely referred and accepted for either diagnostic or screening colonoscopy.

METHODS

Intravenous injection of either 1 mL hyoscine N-butylbromide (n = 340) or 0.9% NaCl solution (n = 334) when withdrawal was started.

METHODS

Polyp detection rate (PDR), adenoma detection rate (ADR), and the advanced lesion detection rate (ALDR), 5% trimmed mean number of polyps, mean withdrawal time.

RESULTS

The cecal intubation rate was 96%. The PDR, ADR, and ALDR were 56% versus 60%, 30% versus 31%, and 14% versus 14% in the hyoscine N-butylbromide and placebo groups, respectively (all P values > .25). The means of the total number of detected, removed, and harvested polyps per patient were 1.13 versus 1.21, 1.03 versus 1.06, and 0.89 versus 0.89 in the hyoscine N-butylbromide and placebo groups, respectively (all P values > .37). Mean withdrawal time was 561 versus 584 seconds in the hyoscine N-butylbromide and placebo groups, respectively (P = .34). Multivariate analysis demonstrated no effect of hyoscine N-butylbromide on the investigated parameters.

CONCLUSIONS

Only experienced colonoscopists participated in the study.

CONCLUSIONS

We found no evidence to support the use of hyoscine N-butylbromide during withdrawal of the colonoscope to improve polyp detection or removal. (

BACKGROUND

ISRCTN25405865.).

انضم إلى صفحتنا على الفيسبوك

قاعدة بيانات الأعشاب الطبية الأكثر اكتمالا التي يدعمها العلم

  • يعمل في 55 لغة
  • العلاجات العشبية مدعومة بالعلم
  • التعرف على الأعشاب بالصورة
  • خريطة GPS تفاعلية - ضع علامة على الأعشاب في الموقع (قريبًا)
  • اقرأ المنشورات العلمية المتعلقة ببحثك
  • البحث عن الأعشاب الطبية من آثارها
  • نظّم اهتماماتك وابقَ على اطلاع دائم بأبحاث الأخبار والتجارب السريرية وبراءات الاختراع

اكتب أحد الأعراض أو المرض واقرأ عن الأعشاب التي قد تساعد ، واكتب عشبًا واطلع على الأمراض والأعراض التي تستخدم ضدها.
* تستند جميع المعلومات إلى البحوث العلمية المنشورة

Google Play badgeApp Store badge