Arabic
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Rapid Communications in Mass Spectrometry 2018-Jan

Microdialysis sampling combined with ultra-high-performance liquid chromatography-tandem mass spectrometry for the determination of geniposide in dialysate of joint cavities in adjuvant arthritis rats.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
يتم حفظ الارتباط في الحافظة
Wen-Yu Wang
Wei Wang
Hong Wu
Shu-Ping Li
Rong Wang
Li Dai
Zheng-Rong Zhang
Jun Fu
Ran Deng
Feng Li

الكلمات الدالة

نبذة مختصرة

BACKGROUND

Microdialysis has been used to detect the concentrations of drugs in tissues. Geniposide (GE), an iridoid glycoside compound, is the main bioactive component of Gardenia jasminoides Ellis fruit. We previously demonstrated that GE could control the activity of cytokines and reduce levels of inflammation in adjuvant arthritis (AA) rats, but the topic of concentration changes over time in the joint synovia of AA is scarcely studied.

METHODS

In this study, microdialysis technique combined with ultra-high-performance liquid chromatography-electrospray ionization coupled with tandem mass spectrometry (UHPLC-ESI-MS/MS) was set up and confirmed to assay GE in the dialysate of the joint cavity in AA rats. Mass detection was conducted in multiple reaction monitoring (MRM) mode with negative electro-spray ionization, and Paeoniflorin (Pae) was used as an internal standard (IS).

RESULTS

A lower limit of quantitation (LLOQ) of 5 ng/mL was found in this method and with good linearity in the range of 5-4000 ng/mL. All the validation data including accuracy, precision, intra and inter-day repeatability and stability meet the requirements. The relative recoveries of GE were determined at approximately 40.01%.

CONCLUSIONS

The measurements based on microdialysis combined with UHPLC-ESI-MS/MS provide a method for sampling and rapid sensitive analysis of GE in dialysate of joint cavity in AA rats. This method should be considered for future pharmacokinetics studies.

انضم إلى صفحتنا على الفيسبوك

قاعدة بيانات الأعشاب الطبية الأكثر اكتمالا التي يدعمها العلم

  • يعمل في 55 لغة
  • العلاجات العشبية مدعومة بالعلم
  • التعرف على الأعشاب بالصورة
  • خريطة GPS تفاعلية - ضع علامة على الأعشاب في الموقع (قريبًا)
  • اقرأ المنشورات العلمية المتعلقة ببحثك
  • البحث عن الأعشاب الطبية من آثارها
  • نظّم اهتماماتك وابقَ على اطلاع دائم بأبحاث الأخبار والتجارب السريرية وبراءات الاختراع

اكتب أحد الأعراض أو المرض واقرأ عن الأعشاب التي قد تساعد ، واكتب عشبًا واطلع على الأمراض والأعراض التي تستخدم ضدها.
* تستند جميع المعلومات إلى البحوث العلمية المنشورة

Google Play badgeApp Store badge