Journal of Cardiothoracic Surgery 2017-Jun

Pitfalls in TAMVI: experience with the repositionable Lotus® Valve System.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
يتم حفظ الارتباط في الحافظة
Paul P Heinisch
Fabien Praz
Bernhard Winkler
Stephan Windecker
Christoph Huber
Thierry Carrel

الكلمات الدالة

نبذة مختصرة

BACKGROUND

Simultaneous transapical implantation of transcatheter heart valves in the native mitral and aortic position may be considered as an alternative to surgical valve replacement in high-risk patients presenting with combined valve disease.

METHODS

A 59-year-old female with severe aortic stenosis, severe mitral stenosis with mild mitral insufficiency, persistent atrial fibrillation, severe chronic obstructive pulmonary disease and NYHA class of IV was evaluated by our interdisciplinary heart team. Due to the calculated Euroscore II, logistic Euroscore with 10% and 17% a decision was made towards a transapical TAVI approach. The implantation of a Sapien 3 (Edwards Lifesciences) valve in the aortic position was performed and the perioperative TEE showed a good result. The preoperative imaging revealed a narrow LVOT with risk for post interventional left ventricular outflow tract obstruction. Accordingly, it was decided against the use of balloon-expanding valves for the mitral valve position in the interdisciplinary team, as it is not repositionable. Instead, it was decided for the use of a Lotus (Boston Scientific) valve, as it is repositionable and therefore possible to retract in case of LVOT obstruction. In the present case of double valve intervention, the implantation attempt of a fully repositionable transcatheter heart valve into the native mitral annulus resulted in acute LVOT obstruction requiring immediate removal of the device. The patient was extubated and experienced uneventful postoperative recovery.

CONCLUSIONS

The case shows that improved preoperative work-up is necessary for better prediction of significant LVOT obstruction following transcatheter mitral valve implantation. In borderline cases, the use of a fully repositionable device is preferred.

انضم إلى صفحتنا على الفيسبوك

قاعدة بيانات الأعشاب الطبية الأكثر اكتمالا التي يدعمها العلم

  • يعمل في 55 لغة
  • العلاجات العشبية مدعومة بالعلم
  • التعرف على الأعشاب بالصورة
  • خريطة GPS تفاعلية - ضع علامة على الأعشاب في الموقع (قريبًا)
  • اقرأ المنشورات العلمية المتعلقة ببحثك
  • البحث عن الأعشاب الطبية من آثارها
  • نظّم اهتماماتك وابقَ على اطلاع دائم بأبحاث الأخبار والتجارب السريرية وبراءات الاختراع

اكتب أحد الأعراض أو المرض واقرأ عن الأعشاب التي قد تساعد ، واكتب عشبًا واطلع على الأمراض والأعراض التي تستخدم ضدها.
* تستند جميع المعلومات إلى البحوث العلمية المنشورة

Google Play badgeApp Store badge