Arabic
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
GE Portuguese Journal of Gastroenterology 2017-Sep

Quality in Colonoscopy: Beyond the Adenoma Detection Rate Fever.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
يتم حفظ الارتباط في الحافظة
Filipe Taveira
Miguel Areia
Luís Elvas
Susana Alves
Daniel Brito
Sandra Saraiva
Ana Teresa Cadime

الكلمات الدالة

نبذة مختصرة

UNASSIGNED

Colonoscopy quality is a hot topic in gastroenterological communities, with several actual guidelines focusing on this aspect. Although the adenoma detection rate (ADR) is the single most important indicator, several other metrics are described and need reporting. Electronic medical reports are essential for the audit of quality indicators; nevertheless, they have proved not to be faultless.

UNASSIGNED

The aim of this study was to analyse and audit quality indicators (apart from ADR) using only our internal electronic endoscopy records as a starting point for improvement.

UNASSIGNED

An analysis of electronically recorded information of 8,851 total colonoscopies from a single tertiary centre from 2010 to 2015 was performed.

UNASSIGNED

The mean patient age was 63.4 ± 8.5 years; 45.5% of them were female, and in 14.6% sedation was used. Photographic documentation was done in 98.4% with 10.7 photographs on average, and 37.4% reports had <8 pictures per exam. Bowel preparation was rated as adequate in 67%, fair in 27% and inadequate in 4.9% of cases. The adjusted caecal intubation rate (CIR) was 92%, while negative predictors were inadequate preparation (OR 119, 95% CI 84-170), no sedation (OR 2.39, 95% CI 1.81-3.15), female gender (OR 1.61, 95% CI 1.38-1.88) and age ≥65 years (OR 1.56, 95% CI 1.34-1.82). In 28% of patients, a snare polypectomy was performed, correlating with adequate preparation (OR 5.75, 95% CI 3.90-8.48), male gender (OR 1.82, 95% CI 1.64-2.01) and age ≥65 years (OR 1.25, 95% CI 1.13-1.37; p < 0.01) as positive predictors. An annual evolution was observed with improvements in photographic documentation (10.7 vs. 12.9; p < 0.001), CIR (91 vs. 94%; p = 0.002) and "adequate" bowel preparation (p = 0.004). Conclusions: There is much more to report than the ADR to ensure quality in colonoscopy practice. Better registry systematization and integrated software should be goals to achieve in the short term.

انضم إلى صفحتنا على الفيسبوك

قاعدة بيانات الأعشاب الطبية الأكثر اكتمالا التي يدعمها العلم

  • يعمل في 55 لغة
  • العلاجات العشبية مدعومة بالعلم
  • التعرف على الأعشاب بالصورة
  • خريطة GPS تفاعلية - ضع علامة على الأعشاب في الموقع (قريبًا)
  • اقرأ المنشورات العلمية المتعلقة ببحثك
  • البحث عن الأعشاب الطبية من آثارها
  • نظّم اهتماماتك وابقَ على اطلاع دائم بأبحاث الأخبار والتجارب السريرية وبراءات الاختراع

اكتب أحد الأعراض أو المرض واقرأ عن الأعشاب التي قد تساعد ، واكتب عشبًا واطلع على الأمراض والأعراض التي تستخدم ضدها.
* تستند جميع المعلومات إلى البحوث العلمية المنشورة

Google Play badgeApp Store badge