Journal of Chromatographic Science 2017-Oct

Reliable GC Method for Related Substances in Divalproex Sodium Drug.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
يتم حفظ الارتباط في الحافظة
S Raghavender Reddy
K Hussain Reddy
P Madhava Reddy
G Amarnatha Reddy
M Narendra Kumar
Hemant Kumar Sharma

الكلمات الدالة

نبذة مختصرة

A specific GC method has been developed, optimized and validated for the determination of seven related substances namely N,N-dimethyl valpronamide, valeric acid, 2-methyl valeric acid, 2-ethyl valeric acid, 2-isopropyl valeric acid, 2-n-butyl valeric acid and 2-propyl-2-pentenoic acid in divalproex sodium (DPS) drug substance. Chromatographic separations of these seven impurities were achieved on DB-FFAP column (30 m × 0.53 mm, 1.0 μm), which consists nitroterephthalic acid modified polyethylene glycol material as stationary phase. DPS is a coordination complex of the sodium valproate and valproic acid (VPA). Nonanoic acid is used as internal standard. All the seven related substances, VPA and nonanoic acid were extracted into dichloromethane and monitored by GC with flame ionization detector. The performance of the developed method was assessed by evaluating specificity, linearity, sensitivity, precision, accuracy and robustness. Forced degradation experiments were conducted to evaluate the degradation behavior of DPS. The established limits of detection (LODs) and limits of quantification (LOQs) values for the related substances were in the ranges of 4-5 and 12-15 μg mL-1, respectively. Further, for VPA, LOD and LOQ values were 4 and 12 μg mL-1, respectively. The correction factors of these related substances with respect to VPA and lie between 0.92 and 1.44. The average recoveries were in the range of 92.4-108.4%.

انضم إلى صفحتنا على الفيسبوك

قاعدة بيانات الأعشاب الطبية الأكثر اكتمالا التي يدعمها العلم

  • يعمل في 55 لغة
  • العلاجات العشبية مدعومة بالعلم
  • التعرف على الأعشاب بالصورة
  • خريطة GPS تفاعلية - ضع علامة على الأعشاب في الموقع (قريبًا)
  • اقرأ المنشورات العلمية المتعلقة ببحثك
  • البحث عن الأعشاب الطبية من آثارها
  • نظّم اهتماماتك وابقَ على اطلاع دائم بأبحاث الأخبار والتجارب السريرية وبراءات الاختراع

اكتب أحد الأعراض أو المرض واقرأ عن الأعشاب التي قد تساعد ، واكتب عشبًا واطلع على الأمراض والأعراض التي تستخدم ضدها.
* تستند جميع المعلومات إلى البحوث العلمية المنشورة

Google Play badgeApp Store badge