Arabic
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Spine 2001-Oct

Slippage mechanism of pediatric spondylolysis: biomechanical study using immature calf spines.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
يتم حفظ الارتباط في الحافظة
K Kajiura
S Katoh
K Sairyo
T Ikata
V K Goel
R I Murakami

الكلمات الدالة

نبذة مختصرة

METHODS

This study analyzed the skeletal-age-dependent strength of the lumbar growth plate to resist anterior shearing forces using the MTS system in the immature calf spine with pars defects.

OBJECTIVE

To clarify the pathomechanism of the skeletal-age-dependent incidence of slippage in pediatric patients with pars defects by comparing the strength of the lumbar growth plate among three skeletal age groups.

BACKGROUND

Isthmic spondylolisthesis occurs and progresses more frequently during the growth period, whereas it is rare afterward. However, little evidence has been demonstrated to elucidate the etiology.

METHODS

For this study, 15 lumbar functional spine units were divided into three groups according to their skeletal ages. Five were from neonates (Group 1), five from calves approximately 2 months old (Group 2), and five from calves about 24 months old (Group 3). An anterior shearing force was applied to each specimen until failure, after bilateral pars defects were created. Failure load (newtons) and displacement at failure (millimeters) were calculated from the load-displacement curve. The site of failure was confirmed by plain radiograph.

RESULTS

All 15 functional spine units failed at the growth plate. The failure load was 242.79 +/- 46.05 N in Group 1, 986.40 +/- 124.16 N in Group 2, and 2024.54 +/- 245.53 N in Group 3. Statistically significant differences were found among the three groups (P < 0.05). The displacement at failure was 7.52 +/- 1.84 mm in Group 1, 11.10 +/- 2.30 mm in Group 2, and 8.15 +/- 2.66 mm in Group 3. There were no significant differences among the groups.

CONCLUSIONS

The results indicate that the strength of the growth plate, the weakest link in this model, against anterior shearing forces depends on the skeletal maturity, and that the biomechanical weakness of the growth plate plays an important role in the slippage mechanism.

انضم إلى صفحتنا على الفيسبوك

قاعدة بيانات الأعشاب الطبية الأكثر اكتمالا التي يدعمها العلم

  • يعمل في 55 لغة
  • العلاجات العشبية مدعومة بالعلم
  • التعرف على الأعشاب بالصورة
  • خريطة GPS تفاعلية - ضع علامة على الأعشاب في الموقع (قريبًا)
  • اقرأ المنشورات العلمية المتعلقة ببحثك
  • البحث عن الأعشاب الطبية من آثارها
  • نظّم اهتماماتك وابقَ على اطلاع دائم بأبحاث الأخبار والتجارب السريرية وبراءات الاختراع

اكتب أحد الأعراض أو المرض واقرأ عن الأعشاب التي قد تساعد ، واكتب عشبًا واطلع على الأمراض والأعراض التي تستخدم ضدها.
* تستند جميع المعلومات إلى البحوث العلمية المنشورة

Google Play badgeApp Store badge