Arabic
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Veterinary Radiology and Ultrasound

Ultrasonographic characteristics of lipiduria in clinically normal cats.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
يتم حفظ الارتباط في الحافظة
Meg D Sislak
Kathy A Spaulding
Debra L Zoran
John E Bauer
James A Thompson

الكلمات الدالة

نبذة مختصرة

Echoes are frequently seen in the urinary bladder of cats during abdominal ultrasound. These have been attributed to hematuria, pyuria, crystalluria, and lipid. However, sonographic findings have not been previously correlated with urinalysis. We prospectively evaluated 40 clinically normal cats via ultrasound, serum chemistry, and urinalysis. Thin layer chromatography was performed on the urine to determine the amount (mg) of lipid subfractions including diacylglycerol, triglyceride, phospholipid, free fatty acid, cholesterol, and cholesterol ester. Ninety percent (36/40) of the cats in our population had sonographic echoes suspended in the urinary bladder, with most having a subjective score of mild echoes (n = 20). None of the sonographic echoes were gravity dependent or caused distal acoustic shadowing, reverberation, or twinkle artifact. Of the cats with sonographic echoes in the urine, 66% (24/36) had no significant findings on urinalysis other than the presence of lipid. The total amount of subjective sonographic echoes was not significantly related to the total amount of fat measured on thin layer chromatography or the number of lipid droplets seen on urinalysis. An increased amount of urine diacylglycerol was significantly associated with clumping of echoes (P = 0.02) and the amount of lipid droplets seen on urinalysis (P = 0.04). An association between increased amounts of urine diacylglycerol and the amount of echoes seen on ultrasound approached significance (P = 0.05). Findings from this study support previously published theories that sonographic echoes within the urinary bladder of clinically normal cats may be due to urine lipid.

انضم إلى صفحتنا على الفيسبوك

قاعدة بيانات الأعشاب الطبية الأكثر اكتمالا التي يدعمها العلم

  • يعمل في 55 لغة
  • العلاجات العشبية مدعومة بالعلم
  • التعرف على الأعشاب بالصورة
  • خريطة GPS تفاعلية - ضع علامة على الأعشاب في الموقع (قريبًا)
  • اقرأ المنشورات العلمية المتعلقة ببحثك
  • البحث عن الأعشاب الطبية من آثارها
  • نظّم اهتماماتك وابقَ على اطلاع دائم بأبحاث الأخبار والتجارب السريرية وبراءات الاختراع

اكتب أحد الأعراض أو المرض واقرأ عن الأعشاب التي قد تساعد ، واكتب عشبًا واطلع على الأمراض والأعراض التي تستخدم ضدها.
* تستند جميع المعلومات إلى البحوث العلمية المنشورة

Google Play badgeApp Store badge