Arabic
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Genomics 1990-Feb

Use of denaturing gradient gel electrophoresis to detect point mutations in the factor VIII gene.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
يتم حفظ الارتباط في الحافظة
M D Traystman
M Higuchi
C K Kasper
S E Antonarakis
H H Kazazian

الكلمات الدالة

نبذة مختصرة

Point mutations in the factor VIII gene are responsible for the majority of cases of hemophilia A, and only a small fraction of these mutations can be recognized by restriction endonuclease analysis. We have now used polymerase chain reaction and denaturing gradient gel electrophoresis to characterize single nucleotide substitutions in the factor VIII gene. Five regions of the gene were studied: exon 8, the 3' end of exon 14, exon 17, exon 18, and exon 24. A GC clamp was attached to the 5' PCR primer to allow detection of the majority of single base changes in DNA fragments ranging from 249 to 356 bp. Ten of eleven known point mutations were definitively separated. Fifty-two patients with unknown mutations were then studied by these methods, and the disease-producing mutation was found in three. First, we identified a new missense mutation in exon 14 which is the likely cause of hemophilia A in one patient (tyrosine changed to cysteine at amino acid residue 1709). Second, we found a new missense mutation in exon 18 in one patient (asparagine to aspartic acid at amino acid residue 1922). Third, a previously described mutation in exon 24 was detected (arginine changed to glutamine at amino acid residue 2209). In addition, a new polymorphic nucleotide substitution was found in intron 7. Moreover, these mutations can be detected when the GC-clamped PCR products from all five regions are run in the same denaturing gel. Our results indicate that denaturing gradient gel electrophoresis can be successfully applied to the analysis of point mutations in large genes whose transcripts are not readily available.

انضم إلى صفحتنا على الفيسبوك

قاعدة بيانات الأعشاب الطبية الأكثر اكتمالا التي يدعمها العلم

  • يعمل في 55 لغة
  • العلاجات العشبية مدعومة بالعلم
  • التعرف على الأعشاب بالصورة
  • خريطة GPS تفاعلية - ضع علامة على الأعشاب في الموقع (قريبًا)
  • اقرأ المنشورات العلمية المتعلقة ببحثك
  • البحث عن الأعشاب الطبية من آثارها
  • نظّم اهتماماتك وابقَ على اطلاع دائم بأبحاث الأخبار والتجارب السريرية وبراءات الاختراع

اكتب أحد الأعراض أو المرض واقرأ عن الأعشاب التي قد تساعد ، واكتب عشبًا واطلع على الأمراض والأعراض التي تستخدم ضدها.
* تستند جميع المعلومات إلى البحوث العلمية المنشورة

Google Play badgeApp Store badge