Arabic
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences 2019-Jul

Validation of a sensitive simultaneous LC-MS/MS method for the quantification of novel anti-cancer thiazolidinedione and quinazolin-4-one derivatives in rat plasma and its application in a rat pharmacokinetic study.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
يتم حفظ الارتباط في الحافظة
Shankar Sengottuvelan
Ritika Uppal
Suneetha Vuppu

الكلمات الدالة

نبذة مختصرة

Thiazolidinediones and quinazolin-4-ones compounds, previously known for their activity against Type 2 diabetes and antifungal activity respectively, are currently being investigated for their anti-cancer activity. The determination of pharmacokinetic parameters for these two classes of compounds using a simultaneous chromatographic method with a low detection limit is a challenge. In this study, a highly sensitive and simultaneous LC-MS/MS-based bioanalytical method was developed and validated in rat plasma for the estimation of four novel anti-cancer compounds, BIT-15-67 and BNT-11, belonging to the Thiazolidinedione class, and BNUA-108 and BNUA-48, from the quinazolin-4-one class. The analytes were extracted from plasma samples by protein precipitation and separated on a short reverse phase Hypersil Phenyl BDS, 50 × 4.6 mm, 2.4 μm column at a column oven temperature of 40 °C. An isocratic mobile phase, a 20:80 (v/v) mixture of 5 mM ammonium acetate solution and acetonitrile containing 0.1% formic acid, was used for the elution at a flow rate of 0.4 mL/min. The analytes and internal standard, sulfaphenazole, were quantified in the multiple reaction monitoring mode using positive electrospray ionization with specific pair of mass by charge ratio. All standard validation parameters were assessed as per current bioanalytical method validation guidelines in rat plasma. The area response for the four analytes was found to be linear over the concentration range of 1.00 to 1000 ng/mL in rat plasma. The signal to noise at LLOQ of 1 ng/mL was adequate for application to different pre-clinical studies. The intra- and inter-day precision were <11% and accuracy deviated -1.8 to 9.60% from the nominal. The mean recovery was high (about 90%) and consistent for all the analytes over the linear dynamic range of the method. This simple, robust and validated method can be employed to determine the rat plasma concentrations of the four selected anticancer compounds in preclinical studies such as the pharmacodynamic and the pharmacokinetic studies including tissue distribution and excretion, and the toxicokinetic studies. In this study, pharmacokinetic parameters were determined using this method for all the four compounds individually following intravenous administration in rats.

انضم إلى صفحتنا على الفيسبوك

قاعدة بيانات الأعشاب الطبية الأكثر اكتمالا التي يدعمها العلم

  • يعمل في 55 لغة
  • العلاجات العشبية مدعومة بالعلم
  • التعرف على الأعشاب بالصورة
  • خريطة GPS تفاعلية - ضع علامة على الأعشاب في الموقع (قريبًا)
  • اقرأ المنشورات العلمية المتعلقة ببحثك
  • البحث عن الأعشاب الطبية من آثارها
  • نظّم اهتماماتك وابقَ على اطلاع دائم بأبحاث الأخبار والتجارب السريرية وبراءات الاختراع

اكتب أحد الأعراض أو المرض واقرأ عن الأعشاب التي قد تساعد ، واكتب عشبًا واطلع على الأمراض والأعراض التي تستخدم ضدها.
* تستند جميع المعلومات إلى البحوث العلمية المنشورة

Google Play badgeApp Store badge