Arabic
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
The Journal of the Association of Physicians of India 2010-Aug

Validity of quantitative unspun urine microscopy, dipstick test leucocyte esterase and nitrite tests in rapidly diagnosing urinary tract infections.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
يتم حفظ الارتباط في الحافظة
N Taneja
S S Chatterjee
M Singh
S Sivapriya
M Sharma
S K Sharma

الكلمات الدالة

نبذة مختصرة

OBJECTIVE

Rapid diagnostic tests can screen out negative samples and can save valuable time and money. The study was conducted to assess the usefulness of leukocyte esterase, nitrate reductase and quantitative microscopic unspun urine wet mount examination in rapidly diagnosing urinary tract infections (UTI).

METHODS

Four hundred and fifty samples were tested by semi-quantitative culture on cysteine lactose electrolyte deficient medium, microscopic examination of unspun urine for significant pyuria, dipstick leucocyte esterase test (LET) and nitrite test (NT). Culture was used as gold standard to evaluate the performance of direct microscopy and dipstick tests.

RESULTS

Urine culture examination revealed significant bacteriuria (>10(5) cfu/ml) 98 (21.8%), in urine samples. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and the diagnostic odds ratio (DOR) of the dip-stick LET were 73.5%, 58.5%, 33.0%, 88.8%, and 3.9 respectively; those of the dip-stick NT were 57.1%, 78.7%, 42.7%, 86.8%, and 4.9 respectively; and those for microscopic significant pyuria detection were 68.4%, 60.8%, 32.7%, 87.3%, and 3.4 respectively. Highest sensitivity (95.9%), NPV (97.9%) and DOR (25.7) was obtained on combining microscopy and dip-stick LET and NT (either of them positive). This can potentially cut costs by 79%.

CONCLUSIONS

Quantitative unspun urine wet mount microscopy and dipstick tests for leucocyte esterase and nitrite test should be added into routine laboratory practices for faster diagnosis of UTI.

انضم إلى صفحتنا على الفيسبوك

قاعدة بيانات الأعشاب الطبية الأكثر اكتمالا التي يدعمها العلم

  • يعمل في 55 لغة
  • العلاجات العشبية مدعومة بالعلم
  • التعرف على الأعشاب بالصورة
  • خريطة GPS تفاعلية - ضع علامة على الأعشاب في الموقع (قريبًا)
  • اقرأ المنشورات العلمية المتعلقة ببحثك
  • البحث عن الأعشاب الطبية من آثارها
  • نظّم اهتماماتك وابقَ على اطلاع دائم بأبحاث الأخبار والتجارب السريرية وبراءات الاختراع

اكتب أحد الأعراض أو المرض واقرأ عن الأعشاب التي قد تساعد ، واكتب عشبًا واطلع على الأمراض والأعراض التي تستخدم ضدها.
* تستند جميع المعلومات إلى البحوث العلمية المنشورة

Google Play badgeApp Store badge