Arabic
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Analytical Methods 2020-Aug

A banana peel/silicon glue coated stir bar for extraction of aspirin, diclofenac, ibuprofen and mefenamic acid followed by high performance liquid chromatography-UV detection

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
يتم حفظ الارتباط في الحافظة
Zahra Jafari
Mohammad Hadjmohammadi

الكلمات الدالة

نبذة مختصرة

In the current study, a green, cost-effective, and bio-degradable additive was used for the preparation of a highly efficient sorbent based on silicon glue. Here, a banana peel was pretreated and mixed with silicon glue. It was proved that the prepared banana peel-silicon glue bar is a reliable sorbent for stir bar sorptive extraction of nonsteroidal anti-inflammatory drugs (NSAIDs) including aspirin, diclofenac, ibuprofen and mefenamic acid in human urine and plasma. Compared to the lab-made sorbents, the prepared sorbent showed high extraction performance, high stability, and satisfactory reproducibility and involved easy preparation. In order to optimize the effective factors, different parameters such as (stirring rate, pH, extraction time, desorption time and elution solvent volume) were optimized using response surface methodology (RSM) through applying Central-Composite Design (CCD). Under the optimum conditions, the linear dynamic ranges of the target analytes were investigated in the range of 0.2-200 μg L-1 with r2 higher than 0.9929. Limits of detection (LODs) and limits of quantification (LOQs) of analytes were in the ranges of 0.04-0.5 and 0.15-1.65, respectively. The reproducibility of the method was also investigated by calculating the relative standard deviation. The RSD was measured to be lower than 4.9%. Bar-to-bar reproducibility at a 100 μg L-1 concentration level was also evaluated to be lower than 5.3% (n = 3). Also, each prepared film can be used up to 64 times without any reduction in extraction performance. Finally, the method was successfully applied for the determination of selected drugs in different biological fluids including urine and plasma samples. The calculated relative recovery in real sample analysis was higher than 90%.

انضم إلى صفحتنا على الفيسبوك

قاعدة بيانات الأعشاب الطبية الأكثر اكتمالا التي يدعمها العلم

  • يعمل في 55 لغة
  • العلاجات العشبية مدعومة بالعلم
  • التعرف على الأعشاب بالصورة
  • خريطة GPS تفاعلية - ضع علامة على الأعشاب في الموقع (قريبًا)
  • اقرأ المنشورات العلمية المتعلقة ببحثك
  • البحث عن الأعشاب الطبية من آثارها
  • نظّم اهتماماتك وابقَ على اطلاع دائم بأبحاث الأخبار والتجارب السريرية وبراءات الاختراع

اكتب أحد الأعراض أو المرض واقرأ عن الأعشاب التي قد تساعد ، واكتب عشبًا واطلع على الأمراض والأعراض التي تستخدم ضدها.
* تستند جميع المعلومات إلى البحوث العلمية المنشورة

Google Play badgeApp Store badge