Arabic
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Analytica Chimica Acta 2020-Apr

Active control of selectivity in organic acid analysis by gas chromatography.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
يتم حفظ الارتباط في الحافظة
Ernest Darko
Kevin Thurbide

الكلمات الدالة

نبذة مختصرة

A new method that allows organic acid selectivity to be dynamically controlled during gas chromatography (GC) is presented. It employs dual in-series stainless steel columns, each coated with a pH-adjusted water stationary phase. The first is a 2 m column coated with a pH 11.4 phase that is connected to a second 11 m column coated with a pH 2.2 phase. In this arrangement, organic acids within sample mixtures are trapped on the first column, while the remaining non-ionizable components continue to separate and elute in the system. Later, by injecting a volatile formic acid solution, the trapped acids are released in-situ to the second column for separation and analysis as desired. The method provides good reproducibility with analyte retention times in consecutive trials yielding an average RSD of 1.9%. Further, depending on column temperature, analytes can be readily retained for periods investigated up to about 30 min without significant deterioration in peak shape. This feature provides considerable control over analyte selectivity and resolution compared to conventional separations. Further, by adding a third conventional GC column in-series, both typical hydrocarbon and enhanced organic acid separations are made possible. The method is applied to the analysis of complex mixtures and matrix interference is found to be significantly minimized. Results indicate that this approach offers beneficial advantages for the selective GC analysis of such acidic analytes.

انضم إلى صفحتنا على الفيسبوك

قاعدة بيانات الأعشاب الطبية الأكثر اكتمالا التي يدعمها العلم

  • يعمل في 55 لغة
  • العلاجات العشبية مدعومة بالعلم
  • التعرف على الأعشاب بالصورة
  • خريطة GPS تفاعلية - ضع علامة على الأعشاب في الموقع (قريبًا)
  • اقرأ المنشورات العلمية المتعلقة ببحثك
  • البحث عن الأعشاب الطبية من آثارها
  • نظّم اهتماماتك وابقَ على اطلاع دائم بأبحاث الأخبار والتجارب السريرية وبراءات الاختراع

اكتب أحد الأعراض أو المرض واقرأ عن الأعشاب التي قد تساعد ، واكتب عشبًا واطلع على الأمراض والأعراض التي تستخدم ضدها.
* تستند جميع المعلومات إلى البحوث العلمية المنشورة

Google Play badgeApp Store badge