Arabic
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Pharmaceutical and Biomedical Analysis 2020-Jan

Development, validation and application of a new HPLC-DAD method for simultaneous quantification of apixaban, dabigatran, edoxaban and rivaroxaban in human plasma.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
يتم حفظ الارتباط في الحافظة
Filipa Gouveia
Joana Bicker
Joana Santos
Marília Rocha
Gilberto Alves
Amílcar Falcão
Ana Fortuna

الكلمات الدالة

نبذة مختصرة

Direct oral anticoagulants (DOACs) have been commonly used for the treatment of venous thromboembolism and for the prevention of stroke in patients with atrial fibrillation. Despite not being initially recommended, monitoring DOACs plasma concentrations is now recognized as essential in emergency situations and in special populations. Moreover, the inter-individual variability found in real studies as well as the high reported non-adherence are corroborating the importance of determining the individual relationship between administered doses, plasma concentrations and pharmacological effects. Therefore, accurate but user-friendly bioanalytical techniques are required to monitor DOACs plasma concentrations in routine clinical practice and phase IV clinical trials. Herein, a fast and simple high performance liquid chromatography (HPLC) method coupled to diode array detection (DAD) was developed, validated and applied to quantify the four currently marketed DOACs (apixaban, edoxaban, dabigatran and rivaroxaban). Sample preparation was performed by solid phase extraction followed by evaporation and concentration of the analytes. Chromatographic separation was accomplished within 6 min on a reversed-phase column (octadecyl-silica packing material; 55 mm × 4 mm, 3 μm particle size), applying a mobile phase composed of an aqueous solution of formic acid (0.1 %, v/v) and acetonitrile, pumped with a gradient elution at 30 °C. The proposed method was linear (r2 ≥ 0.993) within the concentration ranges of 0.017-5.28 μg mL-1, 0.066-5.28 μg mL-1, 0.033-5.28 μg mL-1 and 0.017-5.28 μg mL-1 for apixaban, dabigatran, edoxaban and rivaroxaban, respectively, all of them including the expected range of therapeutic concentrations. Overall, intra- and inter-day trueness of quality control samples, including at the lower limit of quantification (LLOQ), varied between -12.98 to 5.79 %, while imprecision was lower than 16.43 %, supporting that the method is accurate and precise in accordance to international guidelines. Recovery and stability were also assessed and allowed the method to be applied in clinical practice, during therapeutic drug monitoring.

انضم إلى صفحتنا على الفيسبوك

قاعدة بيانات الأعشاب الطبية الأكثر اكتمالا التي يدعمها العلم

  • يعمل في 55 لغة
  • العلاجات العشبية مدعومة بالعلم
  • التعرف على الأعشاب بالصورة
  • خريطة GPS تفاعلية - ضع علامة على الأعشاب في الموقع (قريبًا)
  • اقرأ المنشورات العلمية المتعلقة ببحثك
  • البحث عن الأعشاب الطبية من آثارها
  • نظّم اهتماماتك وابقَ على اطلاع دائم بأبحاث الأخبار والتجارب السريرية وبراءات الاختراع

اكتب أحد الأعراض أو المرض واقرأ عن الأعشاب التي قد تساعد ، واكتب عشبًا واطلع على الأمراض والأعراض التي تستخدم ضدها.
* تستند جميع المعلومات إلى البحوث العلمية المنشورة

Google Play badgeApp Store badge