Arabic
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)

aortic valve insufficiency/قرن الغزال

يتم حفظ الارتباط في الحافظة
مقالاتالتجارب السريريةبراءات الاختراع
الصفحة 1 من عند 23 النتائج

Transfemoral aortic valve implantation in pure native aortic valve insufficiency using the repositionable and retrievable lotus valve.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
Transfemoral aortic valve implantation (TAVI) for the treatment of pure native aortic insufficiency is not routine clinical practice. Absent cusp calcification, missing landmarks in combination with no perfect valve control during release with first-generation TAVI devices resulted in a high rate

Use of the Lotus Transcatheter Valve to Treat Severe Native Aortic Regurgitation.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
Transcatheter aortic valve implantation (TAVI) has become the standard treatment for aortic stenosis in high-risk patients. TAVI for native valve aortic regurgitation is technically more demanding because of a lack of anchoring calcification, a lower index incidence, heterogeneous causes, and larger

Transfemoral Lotus Valve Implantation for Treatment of Postendocarditis Stentless Prosthesis Degeneration With Pure Aortic Regurgitation.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع

Transcatheter Aortic Valve Replacement Using the Repositionable LOTUS Valve: United Kingdom Experience.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
OBJECTIVE This study sought to present the U.K. experience to date with the second-generation LOTUS bioprosthesis (Boston Scientific, Natick, Massachusetts). BACKGROUND First-generation transcatheter aortic valves have limitations. Second-generation repositionable valves may improve on some of those

Transfemoral aortic valve implantation with the repositionable Lotus valve for treatment of patients with symptomatic severe aortic stenosis: results from a single-centre experience.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
OBJECTIVE The aim of the study was to evaluate the procedural and 30-day results for the repositionable Lotus valve in patients undergoing transfemoral aortic valve implantation in a single-centre experience. RESULTS We prospectively enrolled 110 patients with severe symptomatic aortic stenosis

Predictors of Paravalvular Regurgitation After Implantation of the Fully Repositionable and Retrievable Lotus Transcatheter Aortic Valve (from the REPRISE II Trial Extended Cohort).

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
Paravalvular leak (PVL) after transcatheter aortic valve replacement is associated with worse long-term outcomes. The Lotus Valve incorporates an innovative Adaptive Seal designed to minimize PVL. This analysis evaluated the incidence and predictors of PVL after implantation of the Lotus
UNASSIGNED The Lotus valve (Boston Scientific, Natick, MA, USA) is a contemporary transcatheter aortic valve implantation (TAVI) device that is fully repositionable and retrievable to aid implantation and optimise procedural results. The ability to implant the device without routine pre-dilatation

Successful percutaneous paravalvular leak closure followed by transfemoral aortic lotus valve-in-valve implantation in a degenerated surgical bioprosthesis.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
Bioprosthesis degeneration is a relevant clinical issue that is increasingly developing with the higher expectancy of life. Its treatment may be further complicated by the presence of paravalvular leaks, which are usually consequence of tissue friability, annular calcification, and infection. The

Boston Scientific Lotus valve.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
As a result of recent randomised controlled trials and registry observations, transcatheter aortic valve replacement (TAVR) enjoys growing appeal for the treatment of patients at high or extreme risk from surgical aortic valve replacement. However, the current technologies and techniques have

A feasibility study of transaxillary TAVI with the lotus valve.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
OBJECTIVE To assess the feasibility of axillary transcatheter aortic valve implantation (TAVI) using the Lotus valve. BACKGROUND TAVI is used to treat patients with severe aortic stenosis, with transfemoral (TF) access being the safest and most widely used route. In patients unsuitable for this,

Bicuspid Aortic Stenosis Treated With the Repositionable and Retrievable Lotus Valve.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
Transcatheter aortic valve implantation (TAVI) for severe aortic stenosis is a well-established and safe therapeutic option. However, data on TAVI in bicuspid aortic valve stenosis are limited and show a higher rate of moderate-severe aortic regurgitation compared with TAVI for tricuspid aortic

Outcome With the Repositionable and Retrievable Boston Scientific Lotus Valve Compared With the Balloon-Expandable Edwards Sapien 3 Valve in Patients Undergoing Transfemoral Aortic Valve Replacement.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
BACKGROUND New generation devices for transfemoral aortic valve replacement were optimized on valve positioning and reduction of residual aortic regurgitation. We compared 30-day, 12-month, and 24-month outcomes of the Boston Scientific Lotus valve (Lotus) and the balloon-expandable Edwards Sapien 3

Transfemoral aortic valve implantation with the repositionable Lotus valve compared with the balloon-expandable Edwards Sapien 3 valve.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
BACKGROUND The rate of paravalvular aortic insufficiency (AI) with transcatheter aortic valve implantation (TAVI) with first generation devices was higher compared with surgical replacement. Residual AI after TAVI has been linked to an increased mortality rate. We compared two second generation TAVI

Cardiovascular magnetic resonance assessment of 1st generation CoreValve and 2nd generation Lotus valves.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
OBJECTIVE We sought to compare using serial CMR, the quantity of AR and associated valve hemodynamics, following the first-generation CoreValve (Medtronic, Minneapolis, MN) and the second-generation Lotus valve (Boston Scientific, Natick, MA). BACKGROUND Aortic regurgitation (AR) following

Comparison of valve performance of the mechanically expanding Lotus and the balloon-expanded SAPIEN3 transcatheter heart valves: an observational study with independent core laboratory analysis.

يمكن للمستخدمين المسجلين فقط ترجمة المقالات
الدخول التسجيل فى الموقع
The Lotus and SAPIEN3 are second-generation transcatheter heart valves, which are designed to minimize paravalvular aortic regurgitation (PAR) after transcatheter aortic valve replacement (TAVR). We sought to compare both devices for valve performance and with emphasis on PAR by independent core
انضم إلى صفحتنا على الفيسبوك

قاعدة بيانات الأعشاب الطبية الأكثر اكتمالا التي يدعمها العلم

  • يعمل في 55 لغة
  • العلاجات العشبية مدعومة بالعلم
  • التعرف على الأعشاب بالصورة
  • خريطة GPS تفاعلية - ضع علامة على الأعشاب في الموقع (قريبًا)
  • اقرأ المنشورات العلمية المتعلقة ببحثك
  • البحث عن الأعشاب الطبية من آثارها
  • نظّم اهتماماتك وابقَ على اطلاع دائم بأبحاث الأخبار والتجارب السريرية وبراءات الاختراع

اكتب أحد الأعراض أو المرض واقرأ عن الأعشاب التي قد تساعد ، واكتب عشبًا واطلع على الأمراض والأعراض التي تستخدم ضدها.
* تستند جميع المعلومات إلى البحوث العلمية المنشورة

Google Play badgeApp Store badge