Belarusian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Peritoneal Dialysis International 2003-Dec

A randomized, multicenter, open-label trial to establish therapeutic equivalence between the Carex and ultra disconnect systems in patients on continuous ambulatory peritoneal dialysis.

Перакладаць артыкулы могуць толькі зарэгістраваныя карыстальнікі
Увайсці / Зарэгістравацца
Спасылка захоўваецца ў буферы абмену
Loke-Meng Ong
Teck-Onn Lim
Lai-Seong Hooi
Zaki Morad
Poh-Choo Tan
Hin-Seng Wong
Yam-Ngo Lim
Rozina Ghazalli
Chwee-Choon Tan
Wan Shaariah

Ключавыя словы

Рэферат

OBJECTIVE

In the present study, we undertook to establish therapeutic equivalence with respect to peritonitis and technique failure between the Carex disconnect system (B. Braun Carex, Mirandola, Italy) and the standard Ultra system (Baxter Healthcare, Tokyo, Japan) in patients on continuous ambulatory peritoneal dialysis (CAPD).

METHODS

This multicenter, parallel group, randomized controlled trial involved 363 prevalent CAPD patients from 8 centers. The primary endpoint was peritonitis rate; secondary endpoints were technique failure and technical problems encountered. The duration of the evaluation was 1 year.

RESULTS

The risk of peritonitis on Carex varied between the centers. We found a significant treatment-center interaction effect (likelihood ratio test: p = 0.03). The incidence rate ratio (IRR) of peritonitis on Carex as compared with Ultra ranged from 0.4 to 7.2. In two centers, Carex was inferior to Ultra with regard to peritonitis; but, in five centers, the results were inconclusive. Equivalence was not demonstrated in any center. The overall rate of peritonitis in the Carex group was twice that in the Ultra group [IRR: 2.18; 95% confidence interval (CI): 1.51 to 3.14]. Technique failure and technical problems were more common with the Carex system. Technique failure rate at 1 year was 44% in the Carex group and 22% in the Ultra group.

CONCLUSIONS

Equivalence between the Carex disconnect system and the Ultra disconnect system could not be demonstrated. The risk of peritonitis on Carex varied significantly between centers.

Далучайцеся да нашай
старонкі ў facebook

Самая поўная база дадзеных пра лекавыя травы, падтрыманая навукай

  • Працуе на 55 мовах
  • Лячэнне травой пры падтрымцы навукі
  • Распазнаванне траў па малюнку
  • Інтэрактыўная GPS-карта - пазначце травы па месцы (хутка)
  • Чытайце навуковыя публікацыі, звязаныя з вашым пошукам
  • Шукайце лекавыя зёлкі па іх уздзеянні
  • Арганізуйце свае інтарэсы і будзьце ў курсе навінавых даследаванняў, клінічных выпрабаванняў і патэнтаў

Увядзіце сімптом альбо захворванне і прачытайце пра зёлкі, якія могуць дапамагчы, набярыце траву і паглядзіце хваробы і сімптомы, супраць якіх яна выкарыстоўваецца.
* Уся інфармацыя заснавана на апублікаваных навуковых даследаваннях

Google Play badgeApp Store badge