Belarusian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Veterinary Diagnostic Investigation 2011-Mar

Assessment of urine solute and matrix effects on the performance of an enzyme-linked immunosorbent assay for measurement of interleukin-6 in dog urine.

Перакладаць артыкулы могуць толькі зарэгістраваныя карыстальнікі
Увайсці / Зарэгістравацца
Спасылка захоўваецца ў буферы абмену
Michael W Wood
Sushila K Nordone
Shelly L Vaden
Edward B Breitschwerdt

Ключавыя словы

Рэферат

Measurement of cytokine concentrations within body fluids is a means of recognizing subclinical and/or unresolved, infectious and inflammatory states in patients. In the urinary tract, such information may be useful for identifying patients with pyelonephritis, asymptomatic bacteriuria, recurrent infections, and cystitis. One such cytokine, interleukin-6 (IL-6), is recognized as a primary cytokine that is produced following exposure of the urothelium to bacterial virulence factors. Complicating reliable testing for this and other cytokines is the nature of urine itself. Urine varies widely in its composition as indicated by the range of pH and urine specific gravity (USG) observed in healthy patients. An additional variable is the protein and carbohydrate matrix capable of hindering immunologic testing modalities, such as enzyme-linked immunosorbent assays (ELISAs). The purpose of the current study was to examine the role of urine pH, USG, and matrix while optimizing a canine-specific chemiluminescent ELISA for the measurement of IL-6 in the urine of dogs. Urine spiked with IL-6 obtained maximal IL-6 quantitative recoveries of only 55 ± 10% (mean ± 1 standard deviation) when an ELISA optimized for cell culture supernatants was used. The urine matrix and variations in USG were determined to by contributing to this poor IL-6 recovery. Using specific matrix inhibitors and optimal dilutions improved the IL-6 quantitative recovery to 91 ± 5%. Urine pH (5.5-9.5) had no effect. The current work underscores the importance of critically optimizing testing modalities for biomarkers, particularly if they are immunologic in origin.

Далучайцеся да нашай
старонкі ў facebook

Самая поўная база дадзеных пра лекавыя травы, падтрыманая навукай

  • Працуе на 55 мовах
  • Лячэнне травой пры падтрымцы навукі
  • Распазнаванне траў па малюнку
  • Інтэрактыўная GPS-карта - пазначце травы па месцы (хутка)
  • Чытайце навуковыя публікацыі, звязаныя з вашым пошукам
  • Шукайце лекавыя зёлкі па іх уздзеянні
  • Арганізуйце свае інтарэсы і будзьце ў курсе навінавых даследаванняў, клінічных выпрабаванняў і патэнтаў

Увядзіце сімптом альбо захворванне і прачытайце пра зёлкі, якія могуць дапамагчы, набярыце траву і паглядзіце хваробы і сімптомы, супраць якіх яна выкарыстоўваецца.
* Уся інфармацыя заснавана на апублікаваных навуковых даследаваннях

Google Play badgeApp Store badge