Belarusian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Human Reproduction 2003-May

Intraperitoneal levonorgestrel-releasing intrauterine device following uterine perforation: the role of progestins in adhesion formation.

Перакладаць артыкулы могуць толькі зарэгістраваныя карыстальнікі
Увайсці / Зарэгістравацца
Спасылка захоўваецца ў буферы абмену
Ronit Haimov-Kochman
Victoria Doviner
Hagay Amsalem
Diane Prus
Amiram Adoni
Yuval Lavy

Ключавыя словы

Рэферат

BACKGROUND

Intrauterine contraception is a widely used, highly effective means of birth control. Uterine perforation is a serious, albeit rare, complication of intrauterine device (IUD) use. Although uterine perforation by levonorgestrel-releasing (20 micro g/day) intrauterine system (LNG-IUS) has already been reported, the peritoneal adhesion potential of this IUD is unknown.

METHODS

The medical files of all patients diagnosed with an intra-peritoneal IUD between the years 1990-2002 at Hadassah Medical Center were reviewed. Histopathological study of peritoneal adhesion tissue adjacent to levonorgestrel medicated IUD was conducted in one case.

RESULTS

Eight cases of dislocated IUDs were found. Four cases used LNG-IUS and four other cases used copper-IUD. Laparoscopy for IUD removal disclosed mild local peritoneal adhesions between omentum and pelvic organs in all cases. No difference was noted in the appearance of the peritoneum in the presence of either a copper-IUD or LNG-IUS. Histological examination of peritoneal tissue encasing the levonorgestrel-intrauterine system revealed loose connective tissue with aggregates of submesothelial cells with a pseudo-decidual change. Immunohistochemical staining for progesterone receptor was negative.

CONCLUSIONS

The peritoneal adhesions potential of LNG-IUS is low, similar to that of the copper-bearing IUD.

Далучайцеся да нашай
старонкі ў facebook

Самая поўная база дадзеных пра лекавыя травы, падтрыманая навукай

  • Працуе на 55 мовах
  • Лячэнне травой пры падтрымцы навукі
  • Распазнаванне траў па малюнку
  • Інтэрактыўная GPS-карта - пазначце травы па месцы (хутка)
  • Чытайце навуковыя публікацыі, звязаныя з вашым пошукам
  • Шукайце лекавыя зёлкі па іх уздзеянні
  • Арганізуйце свае інтарэсы і будзьце ў курсе навінавых даследаванняў, клінічных выпрабаванняў і патэнтаў

Увядзіце сімптом альбо захворванне і прачытайце пра зёлкі, якія могуць дапамагчы, набярыце траву і паглядзіце хваробы і сімптомы, супраць якіх яна выкарыстоўваецца.
* Уся інфармацыя заснавана на апублікаваных навуковых даследаваннях

Google Play badgeApp Store badge