Belarusian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences 2015-Jan

Rapid and sensitive analysis of nine fungicide residues in chrysanthemum by matrix extraction-vortex-assisted dispersive liquid-liquid microextraction.

Перакладаць артыкулы могуць толькі зарэгістраваныя карыстальнікі
Увайсці / Зарэгістравацца
Спасылка захоўваецца ў буферы абмену
Jiaying Xue
Xiaochu Chen
Wenqing Jiang
Fengmao Liu
Huichen Li

Ключавыя словы

Рэферат

A simple sample pretreatment for simultaneous determination of nine fungicides (triadimefon, picoxystrobin, kresoxim-methyl, diniconazole, epoxiconazole, trifloxystrobin, triticonazole, difenoconazole, and azoxystrobin) in chrysanthemum was developed using matrix extraction-vortex-assisted dispersive liquid-liquid microextraction (ME-VADLLME) prior to gas chromatography with electron capture detection. The target fungicides were firstly extracted with acetonitrile and cleaned with the mixture of primary secondary amine and graphite carbon black. The VADLLME procedure was performed by using toluene with lower density than water as the extraction solvent and the acetonitrile extract as the dispersive solvent, respectively. After vortexing and centrifugation, the fine droplet of toluene was collected on the upper of the mixed toluene/acetonitrile/water system using a 0.1-mL pipettor. Under the optimum conditions, the relative recoveries ranged from 73.9 to 95.1% with relative standard deviations of 3.5-9.7% for all of the analytes. The limits of detection were in the range of (0.005-0.05)×10(-3) mg kg(-1). In the proposed method, the ME step provides more effective cleanup for the chrysanthemum matrix, and VADLLME introduces higher sensitivity with the remarkable enrichment factors up to 88-fold compared with the conventional QuEChERS or SPE. The good performance has demonstrated that ME-VADLLME has a strong potential for application in the multi-residue analysis of complex matrices.

Далучайцеся да нашай
старонкі ў facebook

Самая поўная база дадзеных пра лекавыя травы, падтрыманая навукай

  • Працуе на 55 мовах
  • Лячэнне травой пры падтрымцы навукі
  • Распазнаванне траў па малюнку
  • Інтэрактыўная GPS-карта - пазначце травы па месцы (хутка)
  • Чытайце навуковыя публікацыі, звязаныя з вашым пошукам
  • Шукайце лекавыя зёлкі па іх уздзеянні
  • Арганізуйце свае інтарэсы і будзьце ў курсе навінавых даследаванняў, клінічных выпрабаванняў і патэнтаў

Увядзіце сімптом альбо захворванне і прачытайце пра зёлкі, якія могуць дапамагчы, набярыце траву і паглядзіце хваробы і сімптомы, супраць якіх яна выкарыстоўваецца.
* Уся інфармацыя заснавана на апублікаваных навуковых даследаваннях

Google Play badgeApp Store badge