Български
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Molecular Imaging and Biology 2013-Aug

[68Ga]-albumin-PET in the monitoring of left ventricular function in murine models of ischemic and dilated cardiomyopathy: comparison with cardiac MRI.

Само регистрирани потребители могат да превеждат статии
Вход / Регистрация
Линкът е запазен в клипборда
Andrei Todica
Stefan Brunner
Guido Böning
Sebastian Lehner
Stephan G Nekolla
Moritz Wildgruber
Christopher Übleis
Carmen Wängler
Martina Sauter
Karin Klingel

Ключови думи

Резюме

OBJECTIVE

The purpose of this study is to evaluate left ventricular functional parameters in healthy mice and in different murine models of cardiomyopathy with the novel blood pool (BP) positron emission tomography (PET) tracer [68Ga]-albumin.

METHODS

ECG-gated microPET examinations were obtained in healthy mice, and mice with dilative (DCM) and ischemic cardiomyopathy (ICM) using the novel BP tracer [68Ga]-albumin (AlbBP), as well as [18F]-FDG microPET. Cine-magnetic resonance imaging (MRI) examination performed on a clinical 1.5-T MRI provided the reference standard measurements.

RESULTS

When considering the combined group of healthy controls, DCM and ICM AlbBP-PET significantly overestimated the magnitudes of EDV (AlbBP, 181±86 μl; cine-MRI, 125±80 μl; P<0.001) and ESV (AlbBP, 136±92 μl; cine-MRI, 96±77 μl; P<0.001), whereas the EF (AlbBP, 31±16%; cine-MRI, 33±21%; P=0.910) matched closely to cine-MRI results, as did findings with [18F]-FDG. High correlations were found between the measured cardiac parameters (EDV: R=0.978, ESV: R=0.989, and LVEF: R=0.992).

CONCLUSIONS

Measuring left ventricular function in mice with [68Ga]-albumin BP PET is feasible and showed a high correlation compared to cine-MRI, which was used as a reference standard.

Присъединете се към нашата
страница във facebook

Най-пълната база данни за лечебни билки, подкрепена от науката

  • Работи на 55 езика
  • Билкови лекове, подкрепени от науката
  • Разпознаване на билки по изображение
  • Интерактивна GPS карта - маркирайте билките на място (очаквайте скоро)
  • Прочетете научни публикации, свързани с вашето търсене
  • Търсете лечебни билки по техните ефекти
  • Организирайте вашите интереси и бъдете в крак с научните статии, клиничните изследвания и патентите

Въведете симптом или болест и прочетете за билките, които биха могли да помогнат, напишете билка и вижте болестите и симптомите, срещу които се използва.
* Цялата информация се базира на публикувани научни изследвания

Google Play badgeApp Store badge