Journal of Shoulder and Elbow Surgery 2019-Apr

A biomechanical study of headless compression screws versus a locking plate in radial head fracture fixation.

Само регистрирани потребители могат да превеждат статии
Вход / Регистрация
Линкът е запазен в клипборда
Paul Rebgetz
Luca Daniele
Ian Underhill
Andreas Öchsner
Fraser Taylor

Ключови думи

Резюме

Fixation of a 3-part radial head fracture with cannulated compression screws will show equivalent stiffness to a locking plate under axial load. Debate exists regarding the management of Mason type III fractures, with many believing that open reduction and internal fixation provides advantages over other options. By virtue of their subarticular placement, screw fixation is less likely to cause impingement compared with plate fixation, which can result in loss of rotation and requirement for hardware removal. Insufficient fixation stability can lead to nonunions, necrosis of the radial head, pain, and instability. We tested the mechanical stability of fixation of simulated radial head fractures using headless compression screws compared with standard plate construct.Standardized test constructs were created with repeatable osteotomy cuts and hardware placement on each Synbone model (Synbone AG, Malans, Switzerland). We presectioned 22 proximal radius Synbone models to simulate a 3-part radial head fracture. The models were fixed using a radial head locking plate or headless compression screws in a tripod construct. The constructs were potted into a compression test jig using 2-part epoxy resin. Compression testing was performed using a 30-kN Instron Universal machine (Instron, Norwood, MA, USA). The compression tool was spherical, representing the surface of the capitellum.There was no significant difference between the stiffness of the Synbone constructs under axial load.There was no significant difference between fixation stiffness of a 3-part radial head fracture with headless compression screws in a tripod structure vs. a locking plate in Synbone. Further study is required to allow clinical application.

Присъединете се към нашата
страница във facebook

Най-пълната база данни за лечебни билки, подкрепена от науката

  • Работи на 55 езика
  • Билкови лекове, подкрепени от науката
  • Разпознаване на билки по изображение
  • Интерактивна GPS карта - маркирайте билките на място (очаквайте скоро)
  • Прочетете научни публикации, свързани с вашето търсене
  • Търсете лечебни билки по техните ефекти
  • Организирайте вашите интереси и бъдете в крак с научните статии, клиничните изследвания и патентите

Въведете симптом или болест и прочетете за билките, които биха могли да помогнат, напишете билка и вижте болестите и симптомите, срещу които се използва.
* Цялата информация се базира на публикувани научни изследвания

Google Play badgeApp Store badge