Clinical Hemorheology and Microcirculation 2012

Contrast enhanced ultrasound (CEUS) and time intensity curve (TIC) analysis in compartment syndrome: first results.

Само регистрирани потребители могат да превеждат статии
Вход / Регистрация
Линкът е запазен в клипборда
S Geis
S Gehmert
P Lamby
J Zellner
C Pfeifer
L Prantl
E M Jung

Ключови думи

Резюме

OBJECTIVE

Purpose of this study was to monitor changes of microcirculation in acute compartment syndrome using contrast enhanced ultrasound (CEUS) and to assess the modified perfusion with a special quantification software.

METHODS

8 patients with trauma of the lower limb or the upper extremity were enrolled after acute compartment syndrome was diagnosed clinically and by intracompartmental pressure measurement. The qualitative analysis of the corresponding compartment was assessed using B-scan mode and CEUS simultaneously. CEUS was performed using a multifrequence probe (6-9 MHz, LOGIQ E9 GE) after a i.v. bolus injection of 2 × 2.4 ml contrast agent (SonoVue(®), Bracco, Italy). Digital raw data were stored as cine loops up to 2 minutes. Retrospectively semiquantitative perfusion analysis was performed using time intensity curve analysis and the quantification software QONTRAST(®).

RESULTS

6 out of 8 patients had to be operated due to clinical symptoms and to a pressure perfusion gradient lower than 30 mm Hg. 2 out of 8 were treated conservatively. In all patients haematomas were seen in B-scan mode. No necrosis could be detected. In the TIC analysis low levels of time to peak (20.0 ± 12.1) and area under the curve (118.4 ± 87.8) were observed in acute compartment syndrome. Similarly results have been obtained using the perfusions parameter PEAK (11.1 ± 5.7), time to PEAK (14.7 ± 9.7), regional blood volume (257.1 ± 192.6), and regional blood flow (12.1 ± 6.5) in QONTRAST(®) perfusion software.

CONCLUSIONS

CEUS may be capable of differing between acute compartment syndrome and imminent compartment syndrome.

Присъединете се към нашата
страница във facebook

Най-пълната база данни за лечебни билки, подкрепена от науката

  • Работи на 55 езика
  • Билкови лекове, подкрепени от науката
  • Разпознаване на билки по изображение
  • Интерактивна GPS карта - маркирайте билките на място (очаквайте скоро)
  • Прочетете научни публикации, свързани с вашето търсене
  • Търсете лечебни билки по техните ефекти
  • Организирайте вашите интереси и бъдете в крак с научните статии, клиничните изследвания и патентите

Въведете симптом или болест и прочетете за билките, които биха могли да помогнат, напишете билка и вижте болестите и симптомите, срещу които се използва.
* Цялата информация се базира на публикувани научни изследвания

Google Play badgeApp Store badge