中文(繁體)
Digestive Surgery 2014

Safety and efficacy of a novel, dry powder fibrin sealant for hemostasis in hepatic resection.

Само регистрирани потребители могат да превеждат статии
Вход / Регистрация
Линкът е запазен в клипборда
Karin Ruitenbeek
N Ayez
C Verhoef
J Hans W de Wilt
Jan Bottema
Arjen M Rijken
Monique van Rij
Jaap Koopman
Linda A Zuckerman
Paul Frohna

Ключови думи

Резюме

OBJECTIVE

Fibrocaps is a dry powder fibrin sealant containing human plasma-derived fibrinogen and thrombin. The safety, efficacy, and application methods for Fibrocaps were evaluated in an exploratory, first-in-human, noncomparative, clinical study.

METHODS

Patients with minor bleeding/oozing after elective partial hepatic resection had Fibrocaps applied to the bleeding site either directly from the vial or from a spray device, with manual pressure applied using a cellulose, collagen, or gelatin sponge, if needed. Safety was evaluated at screening and postoperative days 1, 2, and 5, and weeks 4 and 12. The formation of anti-thrombin antibodies was assessed at baseline, and after 4 and 12 weeks. Time to hemostasis (TTH) within 10 min was determined.

RESULTS

Twenty-nine patients were treated with Fibrocaps; 6 experienced serious adverse events that were not related to the course of treatment. Adverse events occurring in >10% of patients were nausea, constipation, hypotension, obstipation, hypokalemia, and postoperative pain. Most adverse events were mild or moderate in severity. No patient developed anti-thrombin antibodies. The percentage of patients who achieved hemostasis was 93%; the median TTH was 3.8 min (range 0.3-10.3). Manual pressure was applied with Fibrocaps in 19 patients and considered beneficial in most.

CONCLUSIONS

Fibrocaps was well tolerated in patients undergoing elective hepatic resection and resulted in rapid hemostasis. These safety and efficacy results support further clinical testing of this ready-to-use fibrin sealant as an adjunct to surgical hemostasis.

Присъединете се към нашата
страница във facebook

Най-пълната база данни за лечебни билки, подкрепена от науката

  • Работи на 55 езика
  • Билкови лекове, подкрепени от науката
  • Разпознаване на билки по изображение
  • Интерактивна GPS карта - маркирайте билките на място (очаквайте скоро)
  • Прочетете научни публикации, свързани с вашето търсене