Български
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Ma zui xue za zhi = Anaesthesiologica Sinica 1993-Jun

The influence of position and PEEP on arterial blood gas during operation.

Само регистрирани потребители могат да превеждат статии
Вход / Регистрация
Линкът е запазен в клипборда
C M Liou
C H Lin
H M Kang
Y C Liu
H S Tso

Ключови думи

Резюме

From December, 1990 to December, 1991, we studied the influence of PEEP and positional change to arterial blood gas in 60 ASA class II or III, aged 20 to 65 years, non-obese patients. The patients were assigned randomly into six groups. Group 1: head down position without PEEP. Group 2: head down position with PEEP 5 cmH2O. Group 3: lithotomy position without PEEP. Group 4: lithotomy position with PEEP 5 cmH2O. Group 5: supine position without PEEP. Group 6: supine position with PEEP 5 cmH2O. Blood gas analysis were performed at 5, 15, 30, 60, 120, and 180 minutes after positional change in group 1-4 and after anesthesia in group 5 and 6. The ventilator settings were: tidal volume -10 ml x 25 x (height in meters)2, rate 8/min. The results of significant difference inter-grouply were: PaO2 at 15 minutes; PaCO2 at 5 minutes; pH at 60, 120, and 180 minutes; base excess (BE) at 120 and 180 minutes. As the time progressed, PaO2 decreased in group 1, 2, and 3; PaCO2 decreased in group 3 and 5; pH decreased in group 3; BE decreased in all groups. PaCO2 were between 30-40 mmHg and no hypocarbia produced in all groups. In conclusion, ventilation of the non-obese patient based on 10 ml x 25 x (height in meters)2 x 8/min produce normocarbia and PaO2 more than 80 mmHg with 50% oxygen. No significant difference of PaO2 were found whether there were position change or PEEP 5 cmH2O.

Присъединете се към нашата
страница във facebook

Най-пълната база данни за лечебни билки, подкрепена от науката

  • Работи на 55 езика
  • Билкови лекове, подкрепени от науката
  • Разпознаване на билки по изображение
  • Интерактивна GPS карта - маркирайте билките на място (очаквайте скоро)
  • Прочетете научни публикации, свързани с вашето търсене
  • Търсете лечебни билки по техните ефекти
  • Организирайте вашите интереси и бъдете в крак с научните статии, клиничните изследвания и патентите

Въведете симптом или болест и прочетете за билките, които биха могли да помогнат, напишете билка и вижте болестите и симптомите, срещу които се използва.
* Цялата информация се базира на публикувани научни изследвания

Google Play badgeApp Store badge