Български
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Herz 2019-Jan

Transcatheter aortic valve replacement in atypical valve anatomy using the Lotus valve : A Chinese single-center experience.

Само регистрирани потребители могат да превеждат статии
Вход / Регистрация
Линкът е запазен в клипборда
Q Xu
X Liu
J Jiang
Y He
Q Zhu
F Gao
F Du
W He
J Cheng
M Kong

Ключови думи

Резюме

In the West, the safety and efficacy of the Lotus valve have been demonstrated; however, data in the Chinese population are still lacking. Few studies have compared the clinical outcomes of transcatheter aortic valve replacement (TAVR) with the Lotus valve in patients with bicuspid or tricuspid aortic valve stenosis. Our aim was to assess TAVR outcomes with the Lotus aortic valve in a Chinese patient cohort.In total, 23 symptomatic, high-surgical risk patients with severe aortic valve stenosis were enrolled. Among them, nine patients (39%) had bicuspid aortic valves, and three patients had a large annulus dimension. The Lotus valve was successfully implanted in all patients. To facilitate accurate positioning, partial re-sheathing was attempted in ten patients (43.5%), while one patient had a full retrieval. One-year clinical follow-up was completed in all patients.

RESULTS
There were no deaths, strokes, or major adverse cardiac and cerebrovascular events in 22 of the 23 patients at 30 days; the all-cause mortality rate at 1 year was 4.4% (1 of 23 patients). The mean aortic valve gradient decreased from 51.5 ± 8.8 mm Hg at baseline to 13.4 ± 4.9 mm Hg (p < 0.001) and the valve area increased from 0.6 ± 0.2 cm2 to 1.5 ± 0.4 cm2 (p < 0.001) at 30 days. Paravalvular leakage was absent or mild (22%), and no patient had severe paravalvular leakage. Six patients (26.1%) required a postprocedural pacemaker. There was no difference regarding the procedural and the 1‑year outcomes between patients with bicuspid and tricuspid aortic valve stenosis.

Our single-center experience demonstrated that the Lotus valve is feasible and effective for Chinese patients with aortic valve stenosis, including atypical cases with bicuspid aortic valves or large aortic annulus size.

Присъединете се към нашата
страница във facebook

Най-пълната база данни за лечебни билки, подкрепена от науката

  • Работи на 55 езика
  • Билкови лекове, подкрепени от науката
  • Разпознаване на билки по изображение
  • Интерактивна GPS карта - маркирайте билките на място (очаквайте скоро)
  • Прочетете научни публикации, свързани с вашето търсене
  • Търсете лечебни билки по техните ефекти
  • Организирайте вашите интереси и бъдете в крак с научните статии, клиничните изследвания и патентите

Въведете симптом или болест и прочетете за билките, които биха могли да помогнат, напишете билка и вижте болестите и симптомите, срещу които се използва.
* Цялата информация се базира на публикувани научни изследвания

Google Play badgeApp Store badge