International Journal of Cardiology 2015-Sep

Transfemoral aortic valve implantation with the repositionable Lotus valve compared with the balloon-expandable Edwards Sapien 3 valve.

Само регистрирани потребители могат да превеждат статии
Вход / Регистрация
Линкът е запазен в клипборда
Jochen Wöhrle
Birgid Gonska
Christoph Rodewald
Ulrike Trepte
Sabrina Koch
Dominik Scharnbeck
Julia Seeger
Sinisa Markovic
Wolfgang Rottbauer

Ключови думи

Резюме

BACKGROUND

The rate of paravalvular aortic insufficiency (AI) with transcatheter aortic valve implantation (TAVI) with first generation devices was higher compared with surgical replacement. Residual AI after TAVI has been linked to an increased mortality rate. We compared two second generation TAVI devices - the repositionable Lotus valve with the balloon-expandable Edwards Sapien 3 valve - regarding procedural and 30 day outcome.

RESULTS

In 78 patients with severe aortic stenosis undergoing transfemoral TAVI we evaluated post-procedural paravalvular AI, device success and early safety according to VARC criteria. Valve size was based on a 256-multislice computed tomography. Patients were followed for 30 days. The Lotus valve (N = 26) and the Edwards Sapien 3 valve (N = 52) were implanted under fluoroscopic guidance. Baseline characteristics were similar between groups. Perimeter derived annulus diameter did not differ with 25.7 ± 1.6mm for Lotus and 25.2 ± 2.1mm for Edwards Sapien 3 patients. After TAVI aortography and transthoracic echocardiography revealed no moderate or severe AI. The rate of mild AI was 12% for Lotus and 15% for Edwards Sapien 3 (p = 0.62). There were no deaths, stroke, annulus rupture or coronary obstruction. Device success was 96% and 98% (p = 0.61), early safety according to VARC 11.5% in both groups (p = 1.0) and the need for pacemaker implantation 27% and 4% (p < 0.003), respectively.

CONCLUSIONS

TAVI with second-generation devices was associated with no moderate or severe AI and a low rate of mild AI. Device success was high for Lotus and Edwards Sapien 3 while the need for permanent pacemaker was significantly higher with the Lotus valve.

Присъединете се към нашата
страница във facebook

Най-пълната база данни за лечебни билки, подкрепена от науката

  • Работи на 55 езика
  • Билкови лекове, подкрепени от науката
  • Разпознаване на билки по изображение
  • Интерактивна GPS карта - маркирайте билките на място (очаквайте скоро)
  • Прочетете научни публикации, свързани с вашето търсене
  • Търсете лечебни билки по техните ефекти
  • Организирайте вашите интереси и бъдете в крак с научните статии, клиничните изследвания и патентите

Въведете симптом или болест и прочетете за билките, които биха могли да помогнат, напишете билка и вижте болестите и симптомите, срещу които се използва.
* Цялата информация се базира на публикувани научни изследвания

Google Play badgeApp Store badge