Български
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing 2020-Jan

Aortic Valve Replacement

Само регистрирани потребители могат да превеждат статии
Вход / Регистрация
Линкът е запазен в клипборда
Furqan Rajput
Roman Zeltser

Ключови думи

Резюме

The aortic valve is a semilunar valve with three leaflets, which lies at the junction of left ventricle and aorta. It allows unidirectional blood flow from the left ventricle to the aorta and the rest of the body. Because of the highly complex and sophisticated cellular and molecular functions, the thin valve leaflet can withstand extreme mechanical and hemodynamic forces with every cardiac cycle. Various factors including age and congenital defects can compromise the normal valvular function leading to a wide variety of complications. Although bicuspid aortic valves (BAV) are the most common congenital abnormality, congenital valve defects can range from aortic atresia (missing or incomplete closure of aortic valves) to a sub or supra-valvular stenosis. BAV is reported to have an incidence of 1 to 2% with a male predominance. Lack of microfibrillar proteins during valvulogenesis has been reported to affect the leaflet development where two leaflets are fused to form one large leaflet. It frequently correlates with aortic abnormalities such as aortic dilation (root, ascending and arch) and coarctation of the aorta. The bicuspid aortic valve leaflets can undergo accelerated calcific degeneration because of abnormal hemodynamic forces. Congenital abnormalities including BAV can lead to various valvular complications including aortic stenosis and aortic regurgitation leading to an increased risk to infective endocarditis, which has a reported incidence of 12 to 39% in BAV. Unless severe, BAV generally remains asymptomatic till the age of 50 to 60 years. Aortic stenosis (AS) is a narrowing of the valve aperture reducing the aortic valve area. Increased resistance to blood flow and transvalvular pressure gradient causes increased left ventricle workload causing hypertrophy. Its prevalence increases with age and can be as high as 4.6% in people greater than age 75 years. Being the most common valvular disease in Europe and America, estimates are that 3.5 million people in England alone will have AS by the year 2020. Calcific degeneration leading to stiffening and restriction motion of valve leaflet is the most common cause of AS. Disruption of endothelium lining on the aortic side caused by increased mechanical stress seem to be the inciting event. Posterior leaflets are reported to be affected the most. Rheumatic fever causing inflammation of the leaflets is still the leading cause of AS in developing countries. AS can be asymptomatic or can cause symptoms of syncope, angina and heart failure. Severe AS is fatal with a 50% mortality at 2 years. As per The American College of Cardiology/American Heart Association (ACC/AHA) guidelines, AS is graded severe when the orifice area is less than 1.0 cm, the mean gradient is greater than 40 mmHg or the jet velocity is greater than 4 m/s. Prognosis is poor in symptomatic or severe cases unless the valve is replaced. Up to 30% of patients aged > 75 do not undergo surgical valve replacement either because of technical reasons; this may include porcelain aorta, general frailty, refusal to undergo surgery, and serious comorbid conditions. The operative death risk for surgical aortic valve replacement (SAVR) is as high as 10% in patients with LV dysfunction, chronic renal disease, and advanced age. Trans-catheter aortic valve replacement and trans-catheter aortic valve implantation (TAVR/TAVI) have emerged as a more feasible and less risky option for patients not suitable for surgery. Aortic regurgitation (AR) is the backflow of blood from the aorta to the left ventricle when the valve leaflets fail to coapt. Common causes include congenital defects, calcific degeneration, infective endocarditis, rheumatic fever, and trauma. Ventricular hypertrophy in chronic cases accommodates increased volume to maintain the normal stroke volume and end-diastolic pressure; hence, chronic AR can be asymptomatic for decades. In contrast, with acute cases of AR, ventricles do not have enough time to undergo the needed changes such as hypertrophy to accommodate increased volumes. Because of decreased stroke volume, the heart rate increases to maintain cardiac output but is insufficient to meet the demand resulting in increased left atrial pressure, pulmonary edema and cardiogenic shock. On physical examination, AR murmur is blowing, high-pitched, diastolic, and decrescendo, beginning soon after the aortic component of S (A); it is loudest at the 3rd or 4th left parasternal intercostal space. It also has associations with various other murmurs including: History of Valvular Surgery Dr. Theodore Tuffier, in 1912, used his finger to free the fused leaflets of a stenosed aortic valve. Before the advent of cardiopulmonary bypass (CPB), mitral valve repair involved commissurotomy through access from the left atrial chamber. Thomas Homes Sellors performed first pulmonary valvulotomy in 1948 by using a tenotomy knife. Charles Hufnagel developed the first artificial valve based on a reciprocating ball and cage. It was used to prevent backflow of blood into the ventricles due to aortic insufficiency. CPB machine revolutionized the valve replacement in the anatomical position. Dr. Dwight Harken and his colleagues performed the first successful aortic valve replacement. Later that year, Drs. Albert Starr and Lowell Edwards performed mitral valve replacement. Bioprosthetic valves are closer in function to natural valves but have a limited life expectancy, whereas, Mechanical valves are more durable but require anticoagulation. The choice of valves, among other factors, depends upon the patient’s age and well-being. Mechanical heart valves are known to last for approximately 25 years. Seventy different mechanical heart valves have been developed since 1960. Ball and cage, bi-leaflet, and tilting disc are the common ones. Modification of the ball valve by Dr. Albert Starr and Lowell Edwards entailed developing a cage made of lucite with a silicone elastomer ball. The cage material was later changed to stainless steel and then cobalt-chromium alloys. The Starr-Edward valve also has a Teflon sewing ring, which enabled suturing into mitral and later into the aortic position. Increased thrombogenicity has been a significant issue, for which valves underwent several modifications such as measures to reduce metal contact by covering the struts with cloth and using Silastic shields. Other issues included hemolysis due to excessive rubbing of the ball against the sewing ring and occlusion of coronary ostia because of high profile. Despite these issues, these valves showed the feasibility of prosthetic valve enabling Starr-Edwards to draw design criteria. Basic points included that the valves should be chemically inert, biocompatible, a-traumatic to blood, and non-thrombogenic. In 1965, Kay-Shiley’s non-rotating disc valve replaced the ball with a single disc but demonstrated poor hemodynamics and hemolysis and was discontinued. Bjork-Shiley in 1969 developed a tilting-disc valve, which overcame the problems with the single-disc valve. Free rotation of disc between metal struts allows it to open by tilting at a 60-degree angle. Bjork-Shiley replaced the flat with the convexo-concave disc to create a larger orifice in 1975 but were the object of a recall due to fracture of welded struts. Medtronic Hall valve developed by Dr. Karl Hall and Robert Kaster is the most common tilting disc valve. Perforation in the middle of the disc served as a guide and an improved tilting angle. In 1977, St Jude Medical developed Bi-leaflet valve, which comprised two semi-circular flaps with hinges close to the center of the orifice. Stagnation of blood flow leading to thrombus formation around the hinge region was a problem with the bi-leaflet valve. A newly developed valve resolved this issue with a valve in which the continuous 360-degree rotation around the central axis of the valve ensured an even distribution of blood flow and prevent thrombus formation. Predisposition for thrombosis, embolism, need for lifelong anticoagulation therapy are drawbacks of mechanical valves. Bioprosthetic valves can either be an allograft (cadaver or Ross procedure) or, a xenograft (native or pericardium). The Ross procedure involves replacing the diseased aortic valve with the patient’s own pulmonary valve (autograft) and replace the pulmonary valve with aortic or pulmonary allograft. The pulmonary autograft grows with the patient and does not induce an immunologic response. The most common xenografts are porcine aortic valves and bovine pericardial valves. Lonescu-Shiley developed xenograft valves by using bovine pericardium on a titanium stent in 1971 but was later withdrawn in 1987 due to structural failure including abrasive tears because of fabric-tissue interface and leaflet calcification. Carpentier-Edwards bovine pericardial valve overcame those issues by making some structural modifications, like stitching pericardium to the inside of the fabric and using flexible stent posts. Although biological valves have better hemodynamics compared to mechanical valves, they have a shorter lifespan because of calcification, which stiffens the valve leaflets. Tissues engineering, a field in regenerative medicine restores and maintains the function of living tissues. Skin graft for burn victims is an example. Tissue engineered heart valves (TEHV) are perceived to be non-thrombogenic, and infection resistant. With advancement in material science and culturing techniques, there is the possibility of a TEHV valve that is capable of growing, remodeling and repairing itself as the patients grow. Polymeric valves have been around for over 50 years, but because the earlier versions were prone to calcification and degradation, they were not widely used and instead only used in bridge devices like artificial hearts and left ventricular assist devices. Besides the advantage that they can be produced in various shapes and sizes, they are known to combine the durability of mechanical valves and the hydrodynamic function of bioprosthetic valves. The earliest polymeric valve implanted in a 44-year-old female in 1958 at the mitral position was a polyurethane design with Teflon chordae tendinae. Polyurethane valves have been found to have better hemodynamics compared to bioprosthetic valves and a lower incidence of thrombogenicity than mechanical valves. With advances in material sciences, the future of polymeric valves seems promising.

Присъединете се към нашата
страница във facebook

Най-пълната база данни за лечебни билки, подкрепена от науката

  • Работи на 55 езика
  • Билкови лекове, подкрепени от науката
  • Разпознаване на билки по изображение
  • Интерактивна GPS карта - маркирайте билките на място (очаквайте скоро)
  • Прочетете научни публикации, свързани с вашето търсене
  • Търсете лечебни билки по техните ефекти
  • Организирайте вашите интереси и бъдете в крак с научните статии, клиничните изследвания и патентите

Въведете симптом или болест и прочетете за билките, които биха могли да помогнат, напишете билка и вижте болестите и симптомите, срещу които се използва.
* Цялата информация се базира на публикувани научни изследвания

Google Play badgeApp Store badge