Български
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Analytical Methods 2011-Jan

Determination of in plasma samples by dual-electrode amperometric detection and liquid chromatography

Само регистрирани потребители могат да превеждат статии
Вход / Регистрация
Линкът е запазен в клипборда
Megan Dorris
Craig Lunte

Ключови думи

Резюме

Co-Q10 is a lipid-soluble benzoquinone that is an important factor in free radical scavenging, mitochondrial membrane stability and ATP synthesis. Dietary Co-Q10 is a powerful antioxidant that has been useful in lessening the damage associated with ischemia-reperfusion injuries and aiding in the recovery of myocardial function after myocardial infarction. However, the role of dietary Co-Q10 in oxidative damage and repair is not well understood. Previous LC-EC methods have used packed carbon bed electrodes with high overpotentials that were sufficient to oxidize and reduce several biological compounds, thereby decreasing the selectivity that can be achieved with EC detection. Thin-layer cell dual electrode detection enables monitoring of reduced and oxidized forms of Co-Q10 simultaneously and selectively. The oxidation (+0.45 V vs. Ag/AgCl) and reduction (-0.4 V vs. Ag/AgCl) electrode potentials were optimized to oxidize and reduce the electroactive quinone moiety. The reduced form of Co-Q10 was prepared from the commercially available oxidized form using a Jones reductor. Confirmation of its formation was determined using the current ratios of the peak and half wave potentials from previously generated hydrodynamic voltammograms, using the oxidized form with electrodes in a series configuration. This analytical system was successfully applied to determine basal concentrations of oxidized (510 nM) and reduced (500 nM) Co-Q10 in human plasma. Peak identity of oxidized and reduced Co-Q10 was confirmed by two orthogonal methods: by the current ratios at +0.45 V and +0.25 V and -0.4 V and -0.2 V (vs. Ag/AgCl) as well as by retention time. Detection limits were determined to be 5 nM, with a linear range of three orders of magnitude.

Присъединете се към нашата
страница във facebook

Най-пълната база данни за лечебни билки, подкрепена от науката

  • Работи на 55 езика
  • Билкови лекове, подкрепени от науката
  • Разпознаване на билки по изображение
  • Интерактивна GPS карта - маркирайте билките на място (очаквайте скоро)
  • Прочетете научни публикации, свързани с вашето търсене
  • Търсете лечебни билки по техните ефекти
  • Организирайте вашите интереси и бъдете в крак с научните статии, клиничните изследвания и патентите

Въведете симптом или болест и прочетете за билките, които биха могли да помогнат, напишете билка и вижте болестите и симптомите, срещу които се използва.
* Цялата информация се базира на публикувани научни изследвания

Google Play badgeApp Store badge