Aspects of biocompatibility of two different dialysis membranes: cuprophane and polysulfone.
কীওয়ার্ডস
বিমূর্ত
Intradialytic hypoxemia, leukopenia and coagulation system activation were monitored in 9 uremic patients during hemodialysis with cuprophane (Cu) and polysulfone (Psf) membranes, using the following parameters: polymorphonuclear count (PMN), elastase alpha-1 proteinase inhibitor (EI-alpha 1PI) complex, platelet count, beta-thromboglobulin (BTG), fibronectin (FN) and arterial oxygen tension (PaO2). Our results indicate that 1) intradialytic hypoxemia observed with both membranes does not seem to be exclusively related to the well-known membrane-dependent leukopenia; 2) platelet activation, as demonstrated by the plasma BTG increase, appears to be an exclusive cellulosic membrane-related phenomenon; 3) at the same time platelet activation seems to be the major factor responsible for high FN levels, the highest FN levels occurring concurrently with the lowest platelet count.