Catalan
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Peritoneal Dialysis International 2003-Dec

A randomized, multicenter, open-label trial to establish therapeutic equivalence between the Carex and ultra disconnect systems in patients on continuous ambulatory peritoneal dialysis.

Només els usuaris registrats poden traduir articles
Inicieu sessió / registreu-vos
L'enllaç es desa al porta-retalls
Loke-Meng Ong
Teck-Onn Lim
Lai-Seong Hooi
Zaki Morad
Poh-Choo Tan
Hin-Seng Wong
Yam-Ngo Lim
Rozina Ghazalli
Chwee-Choon Tan
Wan Shaariah

Paraules clau

Resum

OBJECTIVE

In the present study, we undertook to establish therapeutic equivalence with respect to peritonitis and technique failure between the Carex disconnect system (B. Braun Carex, Mirandola, Italy) and the standard Ultra system (Baxter Healthcare, Tokyo, Japan) in patients on continuous ambulatory peritoneal dialysis (CAPD).

METHODS

This multicenter, parallel group, randomized controlled trial involved 363 prevalent CAPD patients from 8 centers. The primary endpoint was peritonitis rate; secondary endpoints were technique failure and technical problems encountered. The duration of the evaluation was 1 year.

RESULTS

The risk of peritonitis on Carex varied between the centers. We found a significant treatment-center interaction effect (likelihood ratio test: p = 0.03). The incidence rate ratio (IRR) of peritonitis on Carex as compared with Ultra ranged from 0.4 to 7.2. In two centers, Carex was inferior to Ultra with regard to peritonitis; but, in five centers, the results were inconclusive. Equivalence was not demonstrated in any center. The overall rate of peritonitis in the Carex group was twice that in the Ultra group [IRR: 2.18; 95% confidence interval (CI): 1.51 to 3.14]. Technique failure and technical problems were more common with the Carex system. Technique failure rate at 1 year was 44% in the Carex group and 22% in the Ultra group.

CONCLUSIONS

Equivalence between the Carex disconnect system and the Ultra disconnect system could not be demonstrated. The risk of peritonitis on Carex varied significantly between centers.

Uneix-te a la nostra
pàgina de Facebook

La base de dades d’herbes medicinals més completa avalada per la ciència

  • Funciona en 55 idiomes
  • Cures a base d'herbes recolzades per la ciència
  • Reconeixement d’herbes per imatge
  • Mapa GPS interactiu: etiqueta les herbes a la ubicació (properament)
  • Llegiu publicacions científiques relacionades amb la vostra cerca
  • Cerqueu herbes medicinals pels seus efectes
  • Organitzeu els vostres interessos i estigueu al dia de les novetats, els assajos clínics i les patents

Escriviu un símptoma o una malaltia i llegiu sobre herbes que us poden ajudar, escriviu una herba i vegeu malalties i símptomes contra els quals s’utilitza.
* Tota la informació es basa en investigacions científiques publicades

Google Play badgeApp Store badge