Circulation 1989-Nov

Assessment of left ventricular functional preservation during isolated cardiac valve operations.

Només els usuaris registrats poden traduir articles
Inicieu sessió / registreu-vos
L'enllaç es desa al porta-retalls
D H Harpole
J S Rankin
W G Wolfe
L R Smith
W G Young
F M Clements
R H Jones

Paraules clau

Resum

To evaluate intraoperative changes in myocardial performance during valvular operations, ventricular functional measurements were obtained in 16 patients before and after elective cardiac valvular replacement. Six patients had mitral regurgitation, four had mitral stenosis, and six had calcific aortic stenosis; all patients underwent isolated mitral or aortic valve replacement. Cold potassium crystalloid cardioplegia, topical hypothermia, and low-flow systemic hypothermia were employed uniformly. Just before and 10 minutes after cardiopulmonary bypass was discontinued, left ventricular pressure and volume data were recorded at four to five different steady-state levels of filling produced by blood infusion or withdrawal from the aortic cannula (mean end-diastolic pressure range, 10-22 mm Hg; mean end-diastolic volume range, 120-168 ml). Portable first-pass radionuclide ventriculography and simultaneous micromanometry were used for construction of left ventricular pressure-volume loops from which stroke work and end-diastolic volume were calculated. Two-dimensional transesophageal echocardiograms also were recorded, and epicardial pacing maintained heart rate as constant as possible. As compared with prebypass measurements, echocardiographic left ventricular wall volume changed insignificantly after the valvular procedures (178-181 ml/m2, p greater than 0.5). The stroke work-end-diastolic volume relationship before and after operation was highly linear in all studies (mean = 0.97). The slope and x intercept of this relationship did not change significantly after operation, indicating a stable level of left ventricular function (from 12.7 x 10(4) to 10.0 x 10(4) ergs/ml and from 67 to 57 ml, respectively; p greater than 0.3).(ABSTRACT TRUNCATED AT 250 WORDS)

Uneix-te a la nostra
pàgina de Facebook

La base de dades d’herbes medicinals més completa avalada per la ciència

  • Funciona en 55 idiomes
  • Cures a base d'herbes recolzades per la ciència
  • Reconeixement d’herbes per imatge
  • Mapa GPS interactiu: etiqueta les herbes a la ubicació (properament)
  • Llegiu publicacions científiques relacionades amb la vostra cerca
  • Cerqueu herbes medicinals pels seus efectes
  • Organitzeu els vostres interessos i estigueu al dia de les novetats, els assajos clínics i les patents

Escriviu un símptoma o una malaltia i llegiu sobre herbes que us poden ajudar, escriviu una herba i vegeu malalties i símptomes contra els quals s’utilitza.
* Tota la informació es basa en investigacions científiques publicades

Google Play badgeApp Store badge