Dental Materials 2008-May

Comparison of Shear Bond Strength, Fatigue Limit and Fatigue Life in resin-bonded metal to enamel bonds.

Només els usuaris registrats poden traduir articles
Inicieu sessió / registreu-vos
L'enllaç es desa al porta-retalls
Pavinee Padipatvuthikul
Lawrence H Mair

Paraules clau

Resum

OBJECTIVE

To compare the Shear Bond Strength (SBS) of resin-bonded metal/enamel bonds with the Fatigue Limit and Fatigue Life of identical joints.

METHODS

285 discs of Ni/Cr-alloy (dia 5 mmx4 mm) were cast and treated by either (1) Sandblasting with aluminium oxide or (2) Sandblast+15 min electrolyticetch in HCl. The discs were bonded to etched enamel (37% HPO4/30 s) using 3 bonding systems. Ten discs of each group were subjected to a shear bond test (SBT) in a Universal Testing Machine5 (CHS=50 mm/min). Seventeen discs of each group were used to determine the Fatigue Limit using the Staircase method (5000 cycles, 4 kg increment). Further batches of 10 discs were subjected to cyclic loads of either 5, 10, or 20 kg to determine the number of cycles at failure (Fatigue Life). The SBS and Fatigue Limit results were compared by correlation analysis. The Fatigue-Life cycles were compared by Weibull analysis to determine the beta (reliability) and alpha (number of cycles) coefficients for the 3 loads.

RESULTS

For all materials and treatments, the Fatigue-Limit results were much lower than the SBS and there was no correlation between the values (r=0.49, p=0.18). The Fatigue Limit for the samples using 5000 cycles ranged from 10.7 to 16.1 MPa. In the Fatigue-Life study, the stress at which the samples were reliably able to withstand more than 1 million cycles (beta>5) was 2.5 MPa.

CONCLUSIONS

The Fatigue Limit of the bonds was much lower than the SBS and there was no correlation between the two values. In this study the Fatigue Limit was not a good predictor of the long term Fatigue-Life failure of the specimens.

Uneix-te a la nostra
pàgina de Facebook

La base de dades d’herbes medicinals més completa avalada per la ciència

  • Funciona en 55 idiomes
  • Cures a base d'herbes recolzades per la ciència
  • Reconeixement d’herbes per imatge
  • Mapa GPS interactiu: etiqueta les herbes a la ubicació (properament)
  • Llegiu publicacions científiques relacionades amb la vostra cerca
  • Cerqueu herbes medicinals pels seus efectes
  • Organitzeu els vostres interessos i estigueu al dia de les novetats, els assajos clínics i les patents

Escriviu un símptoma o una malaltia i llegiu sobre herbes que us poden ajudar, escriviu una herba i vegeu malalties i símptomes contra els quals s’utilitza.
* Tota la informació es basa en investigacions científiques publicades

Google Play badgeApp Store badge