Catalan
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Ultrasonics 2009-Dec

Ultrasound triggered cell death in vitro with doxorubicin loaded poly lactic-acid contrast agents.

Només els usuaris registrats poden traduir articles
Inicieu sessió / registreu-vos
L'enllaç es desa al porta-retalls
J R Eisenbrey
P Huang
J Hsu
M A Wheatley

Paraules clau

Resum

Traditional chemotherapy generally results in systemic toxicity, which also limits drug levels at the area of need. Two ultrasound contrast agents (UCA), with diameters between 1-2 microm in diameter and shell thicknesses of 100-200 nm, composed of poly lactic-acid (PLA), one loaded by surface adsorption and the other loaded by drug incorporation in the shell, were compared in vitro for potential use in cancer therapy. These poly lactic-acid (PLA) UCA platforms contain a gas core that in an ultrasound (US) field can cause the UCA to oscillate or rupture. Following a systemic injection of drug loaded UCA with external application of US focused at the area of interest, this platform could potentially increase drug toxicity at the area of need, while protecting healthy tissue through microencapsulation of the drug. In vitro toxicity in MDA-MB-231 breast cancer cells of the surface-adsorbed and shell-incorporated doxorubicin (Dox) loaded UCA were examined at 5 MHz insonation using a pulse repetition frequency of 100 Hz at varying pressure amplitudes. Both platforms resulted in equivalent cell death compared to free Dox and US when insonated at peak positive pressure amplitudes of 1.26 MPa and above. While no significant changes in cell death were seen for surface adsorbed Dox-UCA with or without insonation, cell death using the platform with Dox incorporated within the shell increased from 16.12% to 25.78% (p=0.0272), approaching double the potency of the platform when insonated at peak positive pressure amplitudes of 1.26 MPa and above. This mechanism is believed to be the result of UCA rupture at higher insonation pressure amplitudes, resulting in more exposed drug and shell surface area as well as increased cellular uptake of Dox containing polymer shell fragments. This study has shown that a polymer UCA with drug housed within the shell may be used for US-triggered cell death. US activation can be used to make a carrier significantly more potent once in the area of need.

Uneix-te a la nostra
pàgina de Facebook

La base de dades d’herbes medicinals més completa avalada per la ciència

  • Funciona en 55 idiomes
  • Cures a base d'herbes recolzades per la ciència
  • Reconeixement d’herbes per imatge
  • Mapa GPS interactiu: etiqueta les herbes a la ubicació (properament)
  • Llegiu publicacions científiques relacionades amb la vostra cerca
  • Cerqueu herbes medicinals pels seus efectes
  • Organitzeu els vostres interessos i estigueu al dia de les novetats, els assajos clínics i les patents

Escriviu un símptoma o una malaltia i llegiu sobre herbes que us poden ajudar, escriviu una herba i vegeu malalties i símptomes contra els quals s’utilitza.
* Tota la informació es basa en investigacions científiques publicades

Google Play badgeApp Store badge