Journal of Pharmaceutical and Biomedical Analysis 2006-Jun

Development and validation of a specific stability indicating high performance liquid chromatographic method for rizatriptan benzoate.

Články mohou překládat pouze registrovaní uživatelé
Přihlášení Registrace
Odkaz je uložen do schránky
B Mallikarjuna Rao
Sivaiah Sangaraju
M K Srinivasu
P Madhavan
M Lalitha Devi
P Rajendra Kumar
K B Chandrasekhar
Ch Arpitha
T Satya Balaji

Klíčová slova

Abstraktní

A gradient, reversed-phase liquid chromatographic (RP-LC) method was developed for the quantitative determination of rizatriptan benzoate, used to treat relieves migraine headache symptoms. The developed method can be also employed for the related substance determination in bulk samples. Forced degradation studies were performed on bulk sample of rizatriptan benzoate using acid (0.5 N hydrochloric acid), base (0.1 N sodium hydroxide), oxidation (3.0% hydrogen peroxide), water hydrolysis, heat (60 degrees C) and photolytic degradation. Mild degradation of the drug substance was observed in base hydrolysis and considerable degradation observed during oxidative stress. The chromatographic method was fine tuned using the samples generated from forced degradation studies. Good resolution between the peaks corresponds to degradation products and the analyte was achieved on Agilent Zorbax SB-CN (250 mm x 4.6 mm, 5 microm) column. The mobile phase consists of a mixture of aqueous potassium di hydrogen ortho phosphate (pH 3.4), acetonitrile and methanol. The stress sample solutions were assayed against the qualified reference standard of rizatriptan benzoate and the mass balance in each case was close to 99.7% indicating that the developed method is stability indicating. Validation of the developed method was carried out as per ICH requirements.

Připojte se k naší
facebookové stránce

Nejúplnější databáze léčivých bylin podložená vědou

  • Funguje v 55 jazycích
  • Bylinné léky podporované vědou
  • Rozpoznávání bylin podle obrázku
  • Interaktivní mapa GPS - označte byliny na místě (již brzy)
  • Přečtěte si vědecké publikace související s vaším hledáním
  • Hledejte léčivé byliny podle jejich účinků
  • Uspořádejte své zájmy a držte krok s novinkami, klinickými testy a patenty

Zadejte symptom nebo chorobu a přečtěte si o bylinách, které by vám mohly pomoci, napište bylinu a podívejte se na nemoci a příznaky, proti kterým se používá.
* Všechny informace vycházejí z publikovaného vědeckého výzkumu

Google Play badgeApp Store badge