Czech
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Kidney International 1980-Oct

Leukopenia, hypoxia, and complement function with different hemodialysis membranes.

Články mohou překládat pouze registrovaní uživatelé
Přihlášení Registrace
Odkaz je uložen do schránky
A I Jacob
G Gavellas
R Zarco
G Perez
J J Bourgoignie

Klíčová slova

Abstraktní

Complement activation during exposure of plasma to cuprophan has been postulated to cause leukopenia and hypoxia in hemodialysis patients. To determine if hypoxia is related to leukopenia and if complement activation leads to a depletion of functional complement components, we dialyzed four patients three times sequentially against each of four types of membranes: cuprophan, regenerated cellulose, cellulose acetate, and polyacrilonitrile. Within 20 min there was a marked leukopenia with cuprophan from 5541 +/- 376 to 1216 +/- 94 (P less than 0.001) and with regenerated cellulose from 5541 +/- 411 to 1533 +/- 203 (P less than 0.001). With cellulose acetate, the change from 5558 +/- 400 to 3783 +/- 341 (P less than 0.001) was less dramatic, and with polyacrilonitrile the fall from 5591 +/- 381 to 464 +/- 401 (P less than 0.02) was minimal. After 2 and 4 hours of dialysis, a rebound leukocytosis was seen with cuprophan, regenerated cellulose, and cellulose acetate, but not with polyacrilonitrile. Transient thrombocytopenia occurred with cuprophan and regenerated cellulose. In spite of the variable degree of leukopenia, all membranes induced a similar and significant hypoxia, which was progressive throughout dialysis, even during the rebound leukocytosis. After 4 hours, the mean PO2 ranged from 91 to 93 mm Hg with all membranes. Functional hemolytic titers of whole complement, C3, C5, and C4 were normal prior to hemodialysis and failed to decrease after 4 hours with any membrane. It is concluded that hemodialysis leukopenia is membrane-dependent and is not the cause of hypoxia. In addition, hemodialysis complement activation does not lead to functional complement depletion and is of no clinical significance.

Připojte se k naší
facebookové stránce

Nejúplnější databáze léčivých bylin podložená vědou

  • Funguje v 55 jazycích
  • Bylinné léky podporované vědou
  • Rozpoznávání bylin podle obrázku
  • Interaktivní mapa GPS - označte byliny na místě (již brzy)
  • Přečtěte si vědecké publikace související s vaším hledáním
  • Hledejte léčivé byliny podle jejich účinků
  • Uspořádejte své zájmy a držte krok s novinkami, klinickými testy a patenty

Zadejte symptom nebo chorobu a přečtěte si o bylinách, které by vám mohly pomoci, napište bylinu a podívejte se na nemoci a příznaky, proti kterým se používá.
* Všechny informace vycházejí z publikovaného vědeckého výzkumu

Google Play badgeApp Store badge