Czech
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of the American College of Cardiology 1992-Oct

Myocardial contrast echocardiography and the transmural distribution of flow: a critical appraisal during myocardial ischemia not associated with infarction.

Články mohou překládat pouze registrovaní uživatelé
Přihlášení Registrace
Odkaz je uložen do schránky
S Kaul
A R Jayaweera
W P Glasheen
F S Villanueva
H P Gutgesell
W D Spotnitz

Klíčová slova

Abstraktní

OBJECTIVE

This study was undertaken to determine whether myocardial contrast echocardiography can be used to estimate the transmural distribution of flow.

BACKGROUND

Myocardial contrast echocardiography has been shown to reliably measure average transmural blood flow during myocardial ischemia. However, there is controversy regarding its ability to determine the transmural distribution of flow.

METHODS

The transmural distribution of flow was measured in 21 open chest anesthetized dogs with use of radiolabeled microspheres and sonicated albumin microbubbles (mean size 4.5 microns). In the 11 Group I dogs, myocardial contrast echocardiography was performed at baseline and during left anterior descending artery stenosis. In five of these dogs, it was also performed during left circumflex artery stenosis. In these dogs large (mean 12 microns) hand-agitated bubbles were also used. In the five Group II dogs, myocardial contrast echocardiography was performed before and 45 s after intracoronary injection of 6 mg of papaverine in the presence of a critical left circumflex artery stenosis. The five Group III dogs were studied during cardiopulmonary bypass at baseline and during left anterior descending artery stenosis. Off-line image analysis of the echocardiographic images was performed and time-intensity curves obtained from these images were correlated with radiolabeled microsphere-derived flows.

RESULTS

The ratios of the parameters derived from the endocardium and epicardium during myocardial contrast echocardiography were found to correlate poorly (ranging from R2 = 0 to R2 = 0.35) with radiolabeled microsphere-derived endocardial/epicardial flow ratios over a wide range of flow ratios (0.01 to 2.58). These results were not influenced either by the location of the regions of interest (left anterior descending vs. left circumflex artery bed) or by the size of the bubbles (4.5 vs. 12 microns).

CONCLUSIONS

Myocardial contrast echocardiography cannot be used to assess the transmural distribution of flow during myocardial ischemia not associated with infarction.

Připojte se k naší
facebookové stránce

Nejúplnější databáze léčivých bylin podložená vědou

  • Funguje v 55 jazycích
  • Bylinné léky podporované vědou
  • Rozpoznávání bylin podle obrázku
  • Interaktivní mapa GPS - označte byliny na místě (již brzy)
  • Přečtěte si vědecké publikace související s vaším hledáním
  • Hledejte léčivé byliny podle jejich účinků
  • Uspořádejte své zájmy a držte krok s novinkami, klinickými testy a patenty

Zadejte symptom nebo chorobu a přečtěte si o bylinách, které by vám mohly pomoci, napište bylinu a podívejte se na nemoci a příznaky, proti kterým se používá.
* Všechny informace vycházejí z publikovaného vědeckého výzkumu

Google Play badgeApp Store badge