Czech
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)

dental caries/horečka

Odkaz je uložen do schránky
Strana 1 z 1949 Výsledek

Experimental heating properties of re-entrant type resonant cavity applicator for deep tumor hyperthermia.

Články mohou překládat pouze registrovaní uživatelé
Přihlášení Registrace
This paper discusses the heating properties of a new type hyperthermia system composed of a re-entrant type resonant cavity applicator for a deep tumor of the abdominal region. In this heating method, a human body is placed between the two inner electrodes, and is heated with electromagnetic fields

Improvement of the resonant cavity applicator for brain tumor hyperthermia - Computer simulation results -.

Články mohou překládat pouze registrovaní uživatelé
Přihlášení Registrace
This paper discusses new methods to control the heating pattern of the prototype resonant cavity applicator for deep tumor hyperthermia treatment. We have already confirmed the effectiveness of the developed heating system with experiments using agar phantoms and computer simulations. Here, the

Design and construction of resonant cavity applicator for brain tumor hyperthermia treatment without contact.

Články mohou překládat pouze registrovaní uživatelé
Přihlášení Registrace
A re-entrant type resonant cavity applicator for brain tumor hyperthermia treatment is presented. In this method, a human brain is placed between the gap of the inner re-entrant cylinders without contact. This cavity has a window for insertion of the human head. Here, first, to design and construct

Cavity Forming Pneumonia Due to Staphylococcus aureus Following Dengue Fever.

Články mohou překládat pouze registrovaní uživatelé
Přihlášení Registrace
While visiting Malaysia, a 22-year-old previously healthy Japanese man developed myalgia, headache, and fever, leading to a diagnosis of classical dengue fever. After improvement and returning to Japan after a five day hospitalization, he developed productive cough several days after defervescing

Heat shock protein 70 in the rat nasal cavity: localisation and response to hyperthermia.

Články mohou překládat pouze registrovaní uživatelé
Přihlášení Registrace
Heat shock proteins (HSPs) are a group of proteins that are rapidly induced in response to physiological stress, including hyperthermia and exposure to toxicants. Thus they may provide a useful index of toxicity in in vitro systems for screening for toxicity. We have recently developed a rat nasal

Sugar, dental caries and the incidence of acute rheumatic fever: a cohort study of Māori and Pacific children.

Články mohou překládat pouze registrovaní uživatelé
Přihlášení Registrace
To determine whether dental caries, as an indicator of cumulative exposure to sugar, is associated with the incidence of acute rheumatic fever and chronic rheumatic heart disease, in Māori and Pacific children aged 5 and 6 years at their first dental visit. A cohort study was undertaken which linked

Development of the re-entrant type resonant cavity applicator for brain tumor hyperthermia - experimental heating results.

Články mohou překládat pouze registrovaní uživatelé
Přihlášení Registrace
A re-entrant type resonant cavity applicator for brain tumor hyperthermia treatment is presented. In this method, a human head is placed between the gap of the inner re-entrant cylinders, and is heated with electromagnetic fields stimulated in the cavity without contact between the surface of the
In this paper, we discuss the improvement of the speed of AIMS (Automatic Impedance Matching System) to automatically make impedance matching for a re-entrant resonant cavity applicator for non-invasive deep brain tumors hyperthermia treatments. We have already discussed the effectiveness of the

Improvement of the resonant cavity applicator for brain tumor hyperthermia - Experimental heating results -.

Články mohou překládat pouze registrovaní uživatelé
Přihlášení Registrace
A re-entrant type resonant cavity applicator for deep tumor hyperthermia treatment was presented. In this method, a human body is placed between the gap of the inner re-entrant cylinders, and is heated with electromagnetic fields stimulated in the cavity without contact between the surface of the

SAR analysis of a re-entrant resonant cavity applicator for brain tumor hyperthermia treatment with a 3-D anatomical human head model.

Články mohou překládat pouze registrovaní uživatelé
Přihlášení Registrace
A re-entrant resonant cavity applicator system for non-invasive brain tumor hyperthermia treatments was presented. We have already confirmed the effectiveness of the heating properties of this heating system with cylindrical agar phantoms and with computer simulations.

A rationale for carboplatin treatment and abdominal hyperthermia in cancers restricted to the peritoneal cavity.

Články mohou překládat pouze registrovaní uživatelé
Přihlášení Registrace
The purpose of this study was to optimize the treatment of cancers restricted to the peritoneal cavity by combining i.p. chemotherapy with abdominal hyperthermia. In vitro experiments demonstrated that the uptake of carboplatin into CC531 tumor cells was increased at temperatures higher than 41.5

Small cylindrical ultrasound sources for induction of hyperthermia via body cavities or interstitial implants.

Články mohou překládat pouze registrovaní uživatelé
Přihlášení Registrace
In this study, small (outside diameter 1 mm) cylindrical ultrasound sources were investigated for induction of hyperthermia in tumours. These ultrasound transducers could be placed in small-diameter body cavities, or they could be used interstitially in brachytherapy catheters. The ultrasound field
OBJECTIVE Previous studies have reported synergistic effects of combined hyperthermia and chemotherapy and/or irradiation. The response to irradiation and chemotherapy of well-oxygenated and vascularized tumors generally is better than that of hypoxic tumors. Therefore, tumor oxygenation is

Adjuvant effect of high-frequency hyperthermia of the abdominal cavity on the course of transplanted leukemia in AKR mice.

Články mohou překládat pouze registrovaní uživatelé
Přihlášení Registrace
The adjuvant effect of high-frequency hyperthermia of the abdominal cavity was studied in 2-month-old mice of highly leukemic AKR strain treated with cyclophosphamide. Weights of organs, parameters of the peripheral blood, and cytological imprints of organs were compared in experimental and control

Development of automatic impedance matching system for hyperthermia treatment using resonant cavity applicator.

Články mohou překládat pouze registrovaní uživatelé
Přihlášení Registrace
In this paper, we discuss a new system to make impedance matching automatically for a re-entrant resonant cavity applicator for brain tumor hyperthermia treatment non-invasively. We have already discussed about the effectiveness of the heating method using manual type impedance matching controller,
Připojte se k naší
facebookové stránce

Nejúplnější databáze léčivých bylin podložená vědou

  • Funguje v 55 jazycích
  • Bylinné léky podporované vědou
  • Rozpoznávání bylin podle obrázku
  • Interaktivní mapa GPS - označte byliny na místě (již brzy)
  • Přečtěte si vědecké publikace související s vaším hledáním
  • Hledejte léčivé byliny podle jejich účinků
  • Uspořádejte své zájmy a držte krok s novinkami, klinickými testy a patenty

Zadejte symptom nebo chorobu a přečtěte si o bylinách, které by vám mohly pomoci, napište bylinu a podívejte se na nemoci a příznaky, proti kterým se používá.
* Všechny informace vycházejí z publikovaného vědeckého výzkumu

Google Play badgeApp Store badge