Czech
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)

lotus edulis/cévní mozková příhoda

Odkaz je uložen do schránky
Strana 1 z 23 Výsledek

Transcatheter Aortic Valve Replacement Using the Repositionable LOTUS Valve: United Kingdom Experience.

Články mohou překládat pouze registrovaní uživatelé
Přihlášení Registrace
OBJECTIVE This study sought to present the U.K. experience to date with the second-generation LOTUS bioprosthesis (Boston Scientific, Natick, Massachusetts). BACKGROUND First-generation transcatheter aortic valves have limitations. Second-generation repositionable valves may improve on some of those

A lotus root-like appearance in carotid stenosis on optical coherence tomography.

Články mohou překládat pouze registrovaní uživatelé
Přihlášení Registrace
An 82-year-old man visited the outpatient clinic of our stroke centre because of dizziness. He had a previous history of stroke without definite sequelae. Severe stenosis in the left proximal internal carotid artery (ICA) was seen on Doppler sonography. Conventional angiography revealed focal severe

A lotus root-like appearance in carotid stenosis on optical coherence tomography.

Články mohou překládat pouze registrovaní uživatelé
Přihlášení Registrace
An 82-year-old man visited the outpatient clinic of our stroke centre because of dizziness. He had a previous history of stroke without definite sequelae. Severe stenosis in the left proximal internal carotid artery (ICA) was seen on Doppler sonography. Conventional angiography revealed focal severe
OBJECTIVE The aim of the study was to evaluate the procedural and 30-day results for the repositionable Lotus valve in patients undergoing transfemoral aortic valve implantation in a single-centre experience. RESULTS We prospectively enrolled 110 patients with severe symptomatic aortic stenosis

Clinical outcomes of the Lotus Valve in patients with bicuspid aortic valve stenosis: An analysis from the RESPOND study.

Články mohou překládat pouze registrovaní uživatelé
Přihlášení Registrace
Patients with bicuspid valves represent a challenging anatomical subgroup for transcatheter aortic valve implantation (TAVI). This analysis evaluated the clinical outcomes of the fully repositionable and retrievable Lotus Valve System in patients with bicuspid aortic valves enrolled in
UNASSIGNED The Lotus valve (Boston Scientific, Natick, MA, USA) is a contemporary transcatheter aortic valve implantation (TAVI) device that is fully repositionable and retrievable to aid implantation and optimise procedural results. The ability to implant the device without routine pre-dilatation

Boston Scientific Lotus valve.

Články mohou překládat pouze registrovaní uživatelé
Přihlášení Registrace
As a result of recent randomised controlled trials and registry observations, transcatheter aortic valve replacement (TAVR) enjoys growing appeal for the treatment of patients at high or extreme risk from surgical aortic valve replacement. However, the current technologies and techniques have

The Lotus Valve System: an In-depth Review of the Technology.

Články mohou překládat pouze registrovaní uživatelé
Přihlášení Registrace
Innovation for transcatheter aortic valve replacement (TAVR) has transformed a medically complex treatment into a standardized procedure. While Edwards SAPIEN and Medtronic CoreValve occupy the market for TAVR in the United States (US), additional valve systems are being developed. The
BACKGROUND New-generation transcatheter heart valves have been developed to reduce complications of transcatheter aortic valve implantation (TAVI). With this study we sought to compare procedural and 30-day outcomes of the new-generation repositionable Boston Scientific Lotus (Lotus) and the
BACKGROUND New generation devices for transfemoral aortic valve replacement were optimized on valve positioning and reduction of residual aortic regurgitation. We compared 30-day, 12-month, and 24-month outcomes of the Boston Scientific Lotus valve (Lotus) and the balloon-expandable Edwards Sapien 3

Effect of aorto-ventricular angulation on procedural success in transcatheter aortic valve replacements with the Lotus Valve system.

Články mohou překládat pouze registrovaní uživatelé
Přihlášení Registrace
OBJECTIVE To determine the effect of aorto-ventricular angulation (AA) on procedural success with the Lotus Valve system. BACKGROUND AA, the angulation of the aortic valve basal plane, may affect the deployment of transcatheter aortic valve replacements (TAVRs). The Lotus Valve system is fully

Transfemoral aortic valve implantation with the repositionable Lotus valve compared with the balloon-expandable Edwards Sapien 3 valve.

Články mohou překládat pouze registrovaní uživatelé
Přihlášení Registrace
BACKGROUND The rate of paravalvular aortic insufficiency (AI) with transcatheter aortic valve implantation (TAVI) with first generation devices was higher compared with surgical replacement. Residual AI after TAVI has been linked to an increased mortality rate. We compared two second generation TAVI

Procedural and 30-day clinical outcomes following transcatheter aortic valve replacement with lotus valve: Results of the RELEVANT study.

Články mohou překládat pouze registrovaní uživatelé
Přihlášení Registrace
OBJECTIVE We report procedural and 30-day clinical outcomes following transcatheter aortic valve replacement (TAVR) with Lotus Valve system in a high-risk population. BACKGROUND Lotus valve is a second-generation TAVR fully repositionable and retrievable device. RELEVANT (REgistry of Lotus valvE for

Transcatheter aortic valve replacement in atypical valve anatomy using the Lotus valve : A Chinese single-center experience.

Články mohou překládat pouze registrovaní uživatelé
Přihlášení Registrace
In the West, the safety and efficacy of the Lotus valve have been demonstrated; however, data in the Chinese population are still lacking. Few studies have compared the clinical outcomes of transcatheter aortic valve replacement (TAVR) with the Lotus valve in patients with bicuspid or

Initial Single-Center Experience With the Fully Repositionable Transfemoral Lotus Aortic Valve System.

Články mohou překládat pouze registrovaní uživatelé
Přihlášení Registrace
BACKGROUND Transcatheter aortic valve replacement (TAVR) has become the standard therapy for patients with severe symptomatic aortic stenosis and unacceptable high risk for surgical aortic valve replacement. Several different devices for TAVR have been introduced so far, each of them with unique
Připojte se k naší
facebookové stránce

Nejúplnější databáze léčivých bylin podložená vědou

  • Funguje v 55 jazycích
  • Bylinné léky podporované vědou
  • Rozpoznávání bylin podle obrázku
  • Interaktivní mapa GPS - označte byliny na místě (již brzy)
  • Přečtěte si vědecké publikace související s vaším hledáním
  • Hledejte léčivé byliny podle jejich účinků
  • Uspořádejte své zájmy a držte krok s novinkami, klinickými testy a patenty

Zadejte symptom nebo chorobu a přečtěte si o bylinách, které by vám mohly pomoci, napište bylinu a podívejte se na nemoci a příznaky, proti kterým se používá.
* Všechny informace vycházejí z publikovaného vědeckého výzkumu

Google Play badgeApp Store badge