Annals of Thoracic and Cardiovascular Surgery 2006-Oct

Aortic root necrosis after surgical treatment using gelatin-resorcinol-formaldehyde (GRF) glue in patients with acute type A aortic dissection.

Kun registrerede brugere kan oversætte artikler
Log ind / Tilmeld
Linket gemmes på udklipsholderen
Shinichi Suzuki
Kiyotaka Imoto
Keiji Uchida
Yoshinori Takanashi

Nøgleord

Abstrakt

BACKGROUND

Although gelatin-resorcinol-formaldehyde (GRF) glue is used for surgical repair of acute type A aortic dissections, late complications possibly ascribed to toxic effects of GRF glue have been reported. We analyzed the benefits and risks of using GRF glue.

METHODS

Between January 1990 and August 2003, 269 consecutive patients underwent emergency operations for acute type A aortic dissection. GRF glue was not used in 47 patients (non-GRF group) who were operated on until May 1995 and was used in the 222 (GRF group) who underwent operation subsequently.

RESULTS

The rate of in-hospital mortality was significantly higher in the non-GRF group (31.9%) than in the GRF group (12.6%) (p<0.0001). In the GRF group, false aneurysms were found in 31 patients (31/194 survivors, 16.0%) 1-65 (mean, 30+/-18) months after initial operation. Reoperation was done in 24 of these patients. At reoperation, the site to which GRF glue was applied had degenerated, and the anastomosis between the aortic root and prosthesis had opened widely, creating a false aneurysm and resulting in aortic regurgitation with prolapse of the coronary cusps. The mortality rate of reoperation was 4.2% (1/24).

CONCLUSIONS

The use of GRF glue improved the short-term outcome of surgery for acute type A aortic dissection, but was associated with a high incidence of false aneurysms forming at the site of proximal anastomosis, where GRF glue had been applied. Patients in whom GRF glue has been used should be carefully followed up after surgery.

Deltag i vores
facebook-side

Den mest komplette database med medicinske urter understøttet af videnskab

  • Arbejder på 55 sprog
  • Urtekurer, der understøttes af videnskab
  • Urtegenkendelse ved billede
  • Interaktivt GPS-kort - tag urter på stedet (kommer snart)
  • Læs videnskabelige publikationer relateret til din søgning
  • Søg medicinske urter efter deres virkninger
  • Organiser dine interesser og hold dig opdateret med nyhedsundersøgelser, kliniske forsøg og patenter

Skriv et symptom eller en sygdom, og læs om urter, der kan hjælpe, skriv en urt og se sygdomme og symptomer, den bruges mod.
* Al information er baseret på offentliggjort videnskabelig forskning

Google Play badgeApp Store badge