Danish
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
American Journal of Dentistry 2003-Jun

Effect of surface penetrating sealant on roughness of posterior composite resins.

Kun registrerede brugere kan oversætte artikler
Log ind / Tilmeld
Linket gemmes på udklipsholderen
Paulo Henrique dos Santos
Simonides Consani
Lourenço Correr Sobrinho
Mário Alexandre Coelho Sinhoreti

Nøgleord

Abstrakt

OBJECTIVE

To verify the effect of surface penetrating sealant on the roughness of posterior resin-based composites before and after mechanical toothbrushing.

METHODS

10 specimens of four different composites (Alert, Definite, Z100 and Prodigy Condensable) were made using a metal matrix (height 2 mm and diameter 4 mm). After 24 hours, the specimens were polished using Sof-Lex discs in sequence: coarse, medium, fine and superfine, each for 40 seconds and, immediately, one of the surfaces was covered with Protect-It surface sealant. All the specimens were examined with a profilometer to measure the initial surface roughness before mechanical toothbrushing at a constant speed of 250 strokes/minute with a total of 30,000 cycles, using a toothbrush and dentifrice containing calcium carbonate as abrasive, under a load of 200 g. After toothbrushing the surface roughness was measured once again. The data were analyzed with ANOVA and the Tukey test at a 95% confidence level.

RESULTS

Mechanical toothbrushing increased the surface roughness of all the composites studied (Alert: 0.7303 +/- 0.0942 microm; Definite: 0.4961 +/- 0.1255 microm; Z100: 0.3428 +/- 0.0841 microm), with the exception of Prodigy Condensable (0.2782 +/- 0.0678 microm) (P > 0.05). The surface penetrating sealant effectively decreased the surface roughness for Alert (0.5435 +/- 0.2182 microm) and Definite (0.2956 +/- 0.0368 microm) (P < 0.05), but had no effect upon Z100 (0.3331 +/- 0.0565 microm) and Prodigy Condensable (0.2760 +/- 0.0920 microm) as these have smaller filler sizes than the other composites tested (P > 0.05).

Deltag i vores
facebook-side

Den mest komplette database med medicinske urter understøttet af videnskab

  • Arbejder på 55 sprog
  • Urtekurer, der understøttes af videnskab
  • Urtegenkendelse ved billede
  • Interaktivt GPS-kort - tag urter på stedet (kommer snart)
  • Læs videnskabelige publikationer relateret til din søgning
  • Søg medicinske urter efter deres virkninger
  • Organiser dine interesser og hold dig opdateret med nyhedsundersøgelser, kliniske forsøg og patenter

Skriv et symptom eller en sygdom, og læs om urter, der kan hjælpe, skriv en urt og se sygdomme og symptomer, den bruges mod.
* Al information er baseret på offentliggjort videnskabelig forskning

Google Play badgeApp Store badge