Danish
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Pharmaceutical and Biomedical Analysis 2019-Oct

Novel amperometric flow-injection analysis of creatinine using a molecularly-imprinted polymer coated copper oxide nanoparticle-modified carbon-paste-electrode.

Kun registrerede brugere kan oversætte artikler
Log ind / Tilmeld
Linket gemmes på udklipsholderen
Nongyao Nontawong
Maliwan Amatatongchai
Suphatsorn Thimoonnee
Saowanee Laosing
Purim Jarujamrus
Chanpen Karuwan
Sanoe Chairam

Nøgleord

Abstrakt

We report a novel amperometric flow-injection (FI) analysis of creatinine based on a sensor comprising copper oxide nanoparticles (CuO) coated with a molecularly-imprinted polymer (CuO@MIP) and decorating a carbon-paste electrode (CPE) to form the CuO@MIP/CPE electrode. The CuO@MIP was synthesized by using CuO as the supporting core, creatinine as the template, methacrylic acid (MAA) as monomer, N, N'-(1,2-dihydroxyethylene)bis(acrylamide) (DHEBA) as cross-linker, and 2,2'-azobis (2-methylpropionitrile) (AIBN) as initiator. Morphology and structural characterization reveal that CuO nanoparticle imprinted sites (CuO) synthesized using a precipitation method, exhibits features that are well suited to creatinine detection: high surface area, good analyte diffusion and adsorption characteristics that provide shorter response times, and large numbers of specific cavities for enhanced analyte capacity and sensitivity. Cyclic voltammetric measurements indicate that our sensor provides excellent performance toward electro-oxidation of creatinine. The amperometric FI system was used to quantitatively determine creatinine at the CuO@MIP/CPE sensor, in a phosphate buffer carrier. The imprinted sensor exhibits excellent performance for creatinine oxidation at an applied potential of +0.35 V and flow rate of 0.6 mL.min-1. The as-prepared sensor exhibits a linear dynamic range for creatinine detection from 0.5 to 200 μM (r2 = 0.995) with a limit of detection of 0.083 μM (S/N = 3). The system exhibits satisfactorily good precision (%RSD = 1.94%, n = 30) and selectivity toward creatinine. There is only approximately 20% loss from initial response after 2 weeks when stored at 4 oC. We successfully applied the FI detection system to detect creatinine in human urine samples.

Deltag i vores
facebook-side

Den mest komplette database med medicinske urter understøttet af videnskab

  • Arbejder på 55 sprog
  • Urtekurer, der understøttes af videnskab
  • Urtegenkendelse ved billede
  • Interaktivt GPS-kort - tag urter på stedet (kommer snart)
  • Læs videnskabelige publikationer relateret til din søgning
  • Søg medicinske urter efter deres virkninger
  • Organiser dine interesser og hold dig opdateret med nyhedsundersøgelser, kliniske forsøg og patenter

Skriv et symptom eller en sygdom, og læs om urter, der kan hjælpe, skriv en urt og se sygdomme og symptomer, den bruges mod.
* Al information er baseret på offentliggjort videnskabelig forskning

Google Play badgeApp Store badge