Danish
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Digestive Surgery 2014

Safety and efficacy of a novel, dry powder fibrin sealant for hemostasis in hepatic resection.

Kun registrerede brugere kan oversætte artikler
Log ind / Tilmeld
Linket gemmes på udklipsholderen
Karin Ruitenbeek
N Ayez
C Verhoef
J Hans W de Wilt
Jan Bottema
Arjen M Rijken
Monique van Rij
Jaap Koopman
Linda A Zuckerman
Paul Frohna

Nøgleord

Abstrakt

OBJECTIVE

Fibrocaps is a dry powder fibrin sealant containing human plasma-derived fibrinogen and thrombin. The safety, efficacy, and application methods for Fibrocaps were evaluated in an exploratory, first-in-human, noncomparative, clinical study.

METHODS

Patients with minor bleeding/oozing after elective partial hepatic resection had Fibrocaps applied to the bleeding site either directly from the vial or from a spray device, with manual pressure applied using a cellulose, collagen, or gelatin sponge, if needed. Safety was evaluated at screening and postoperative days 1, 2, and 5, and weeks 4 and 12. The formation of anti-thrombin antibodies was assessed at baseline, and after 4 and 12 weeks. Time to hemostasis (TTH) within 10 min was determined.

RESULTS

Twenty-nine patients were treated with Fibrocaps; 6 experienced serious adverse events that were not related to the course of treatment. Adverse events occurring in >10% of patients were nausea, constipation, hypotension, obstipation, hypokalemia, and postoperative pain. Most adverse events were mild or moderate in severity. No patient developed anti-thrombin antibodies. The percentage of patients who achieved hemostasis was 93%; the median TTH was 3.8 min (range 0.3-10.3). Manual pressure was applied with Fibrocaps in 19 patients and considered beneficial in most.

CONCLUSIONS

Fibrocaps was well tolerated in patients undergoing elective hepatic resection and resulted in rapid hemostasis. These safety and efficacy results support further clinical testing of this ready-to-use fibrin sealant as an adjunct to surgical hemostasis.

Deltag i vores
facebook-side

Den mest komplette database med medicinske urter understøttet af videnskab

  • Arbejder på 55 sprog
  • Urtekurer, der understøttes af videnskab
  • Urtegenkendelse ved billede
  • Interaktivt GPS-kort - tag urter på stedet (kommer snart)
  • Læs videnskabelige publikationer relateret til din søgning
  • Søg medicinske urter efter deres virkninger
  • Organiser dine interesser og hold dig opdateret med nyhedsundersøgelser, kliniske forsøg og patenter

Skriv et symptom eller en sygdom, og læs om urter, der kan hjælpe, skriv en urt og se sygdomme og symptomer, den bruges mod.
* Al information er baseret på offentliggjort videnskabelig forskning

Google Play badgeApp Store badge