Danish
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Chromatography A 2009-May

Salting-out gradients in centrifugal partition chromatography for the isolation of chlorogenic acids from green coffee beans.

Kun registrerede brugere kan oversætte artikler
Log ind / Tilmeld
Linket gemmes på udklipsholderen
Roman R Romero-González
Robert Verpoorte

Nøgleord

Abstrakt

In addition to sample solubility constraints, the use of polarity gradients in normal-phase centrifugal partition chromatography (CPC) for the purification of complex mixtures is also limited by the instability of biphasic systems as a consequence of dramatic changes in the settling times along the gradient, leading in many cases to column bleeding when working under maximum efficiency conditions. In this paper an electrostriction approach is proposed as a strategy in reversed-phase CPC to fractionate intermediate polarity extracts in a single run by bringing its components into the "sweet spot" in a controlled fashion through a stepwise reduction of salt concentration in the aqueous mobile phase. The salting-out gradient method was successfully tested with the separation of the major chlorogenic acids (CGAs, hydroxycinnamoylquinic acids) present in green coffee beans (5-caffeoylquinic acid (5-CQA), 5-feruloylquinic acid (5-FQA) and 3,5-dicaffeoylquinic acid (3,5-diCQA)) using ethyl acetate-hexane as the stationary phase and an ionic gradient of LiCl (5.0, 2.5 and 0.1M) as the mobile phase in one case and (NH(4))(2)SO(4)/KNO(3) (3.0 and 1.5M/1.5M) in another. Regioisomers of each chlorogenic acid obtained by base-catalyzed isomerisation were also separated by CPC using isocratic elution. The best resolution for both FQAs and diCQAs was achieved with a chloroform-n-butanol-0.01M pH 2.5 phosphate buffer (84:16:100; v/v) system, while CQAs were best isolated using chloroform-n-butanol-0.01M pH 2.5 phosphate buffer/5.0M LiCl (82:18:100; v/v).

Deltag i vores
facebook-side

Den mest komplette database med medicinske urter understøttet af videnskab

  • Arbejder på 55 sprog
  • Urtekurer, der understøttes af videnskab
  • Urtegenkendelse ved billede
  • Interaktivt GPS-kort - tag urter på stedet (kommer snart)
  • Læs videnskabelige publikationer relateret til din søgning
  • Søg medicinske urter efter deres virkninger
  • Organiser dine interesser og hold dig opdateret med nyhedsundersøgelser, kliniske forsøg og patenter

Skriv et symptom eller en sygdom, og læs om urter, der kan hjælpe, skriv en urt og se sygdomme og symptomer, den bruges mod.
* Al information er baseret på offentliggjort videnskabelig forskning

Google Play badgeApp Store badge