Danish
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Analytical Toxicology 2017-Jun

Sensitive Determination of Cannabinoids in Whole Blood by LC-MS-MS After Rapid Removal of Phospholipids by Filtration.

Kun registrerede brugere kan oversætte artikler
Log ind / Tilmeld
Linket gemmes på udklipsholderen
Lambert K Sørensen
Jørgen B Hasselstrøm

Nøgleord

Abstrakt

Direct analysis of Δ9-tetrahydrocannabinol (THC) and other cannabinoids in crude acetonitrile extracts of whole blood by liquid chromatography-tandem mass spectrometry using pneumatically assisted electrospray ionization (LC-ESI-MS-MS) was subjected to pronounced ion suppression from co-eluting phospholipids (PLs). The interferences were mainly caused by the lysophosphatidylcholine and lysophosphatidylethanolamine classes of PLs. The PLs were easily removed from crude extracts by filtration through a sorbent with Lewis acid properties, which typically increased the THC and cannabinol (CBN) signal intensities by a factor of 5. Based on this technique, a simple high-throughput LC-MS-MS method was developed for the determination of cannabinoids in 100 μL samples of whole blood. The lower limits of quantification were 0.2 μg/L for THC, CBN, cannabidiol (CBD) and Δ9-tetrahydrocannabinolic acid A (THCA-A) and 0.5 μg/L for 11-hydroxy-Δ9-tetrahydrocannabinol (THC-OH) and 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THC-COOH). The mean ion suppression levels after clean-up were 10% (THC), 9% (CBN), 17% (CBD), 0% (THC-OH), 2% (THC-COOH) and 9% (THCA-A) at blood concentration levels of 1-10 μg/L. The mean true extraction recoveries were 97% (THC), 101% (CBN), 101% (CBD), 98% (THC-OH), 95% (THC-COOH) and 90% (THCA-A) at the same concentration levels. The relative intra-laboratory reproducibility standard deviations were <9% at concentrations of 1 μg/L or higher. The trueness expressed as the relative bias of the test results was within ±4% at concentrations of 1 μg/L or higher.

Deltag i vores
facebook-side

Den mest komplette database med medicinske urter understøttet af videnskab

  • Arbejder på 55 sprog
  • Urtekurer, der understøttes af videnskab
  • Urtegenkendelse ved billede
  • Interaktivt GPS-kort - tag urter på stedet (kommer snart)
  • Læs videnskabelige publikationer relateret til din søgning
  • Søg medicinske urter efter deres virkninger
  • Organiser dine interesser og hold dig opdateret med nyhedsundersøgelser, kliniske forsøg og patenter

Skriv et symptom eller en sygdom, og læs om urter, der kan hjælpe, skriv en urt og se sygdomme og symptomer, den bruges mod.
* Al information er baseret på offentliggjort videnskabelig forskning

Google Play badgeApp Store badge