Danish
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Biology of the neonate 1998

Value of myocardial hypoxia markers (creatine kinase and its MB-fraction, troponin-T, QT-intervals) and serum creatinine for the retrospective diagnosis of perinatal asphyxia.

Kun registrerede brugere kan oversætte artikler
Log ind / Tilmeld
Linket gemmes på udklipsholderen
J C Möller
B Thielsen
T F Schaible
I Reiss
M Kohl
T Welp
L Gortner

Nøgleord

Abstrakt

Neonatal asphyxia is a major topic of neonatal research. However, no clear-cut physiologic parameters exist which enable an early identification of neonatal infants who are either at risk to develop brain damage or posthypoxic heart failure. Parameters indicating dysfunction of the heart and kidneys as creatinine and creatinine kinase have been evaluated. In our study, 47 asphyxiated infants (umbilical artery pH < 7.18 and either a 1-min Apgar score < 4 or a 5-min Apgar score < 7) were compared to 27 nonasphyxiated controls regarding significant differences in creatinine, creatinine kinase, its MB fraction, and a newly introduced myocardial hypoxia indicator -- troponin T -- to establish the value of these parameters in the retrospective diagnosis of asphyxia. Further we evaluated two subsets of these 47 asphyxiated infants with either subsequent signs of encephalopathy (seizures) or heart failure. Creatinine, creatinine kinase and troponin T were significantly elevated in asphyxiated infants compared with controls; no differences were found in creatinine kinase and its MB fraction. In asphyxiated infants with heart failure, troponin T was significantly higher than in the other asphyxiated infants. However, none of the parameters studied was significantly different in patients with brain damage compared with asphyxiated infants without neurological sequelae. Troponin T has a high positive predictive value in the postnatal diagnosis of asphyxia. The diagnostic power of troponin T equals that of creatinine. However, troponin T is more sensitive in the identification of infants with asphyxia and cardiocirculatory failure than creatinine. Creatinine kinase and its MB fraction have no diagnostic value.

Deltag i vores
facebook-side

Den mest komplette database med medicinske urter understøttet af videnskab

  • Arbejder på 55 sprog
  • Urtekurer, der understøttes af videnskab
  • Urtegenkendelse ved billede
  • Interaktivt GPS-kort - tag urter på stedet (kommer snart)
  • Læs videnskabelige publikationer relateret til din søgning
  • Søg medicinske urter efter deres virkninger
  • Organiser dine interesser og hold dig opdateret med nyhedsundersøgelser, kliniske forsøg og patenter

Skriv et symptom eller en sygdom, og læs om urter, der kan hjælpe, skriv en urt og se sygdomme og symptomer, den bruges mod.
* Al information er baseret på offentliggjort videnskabelig forskning

Google Play badgeApp Store badge