Greek
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Chest 1993-Oct

Accuracy of three pulse oximeters during exercise and hypoxemia in patients with cystic fibrosis.

Μόνο εγγεγραμμένοι χρήστες μπορούν να μεταφράσουν άρθρα
Σύνδεση εγγραφή
Ο σύνδεσμος αποθηκεύεται στο πρόχειρο
D M Orenstein
S E Curtis
P A Nixon
E R Hartigan

Λέξεις-κλειδιά

Αφηρημένη

To evaluate the reliability of noninvasive oximeters during exercise in patients with cystic fibrosis (CF), we studied 9 patients during exercise tests, using 3 devices (Hewlett-Packard 47201A, Biox-Ohmeda 3700, Nellcor 100), comparing oximetry readings with arterial blood co-oximetry. Fifty samples from preexercise, exercise, and recovery were collected; and paired measurements were analyzed for bias (arterial blood gas SaO2--noninvasive SaO2) and precision (1 SD of the bias). Values were available for the Hewlett-Packard and the Biox-Ohmeda at all 50 collection times. The Nellcor failed to read on four occasions, all during exercise. The accuracy of the Biox-Ohmeda readings was significantly worse during exercise than rest, while the Nellcor and the Hewlett-Packard performance did not differ significantly between exercise and rest. During hypoxemia (SaO2 < 90 percent as determined by co-oximetry on arterial blood), the Biox-Ohmeda and Nellcor consistently overestimated saturation, with mean bias of -6.1 percent and -3.0 percent, respectively. The Hewlett-Packard was more reliable and valid during hypoxemia, with a mean bias of -1.0 percent. The Nellcor read significantly more accurately in the six patients with severe digital clubbing than in the three patients with mild digital clubbing. It is important to be aware of possible limitations of noninvasive oximeters before accepting them as accurate.

Γίνετε μέλος της σελίδας
μας στο facebook

Η πληρέστερη βάση δεδομένων φαρμακευτικών βοτάνων που υποστηρίζεται από την επιστήμη

  • Λειτουργεί σε 55 γλώσσες
  • Βοτανικές θεραπείες που υποστηρίζονται από την επιστήμη
  • Αναγνώριση βοτάνων με εικόνα
  • Διαδραστικός χάρτης GPS - ετικέτα βότανα στην τοποθεσία (σύντομα)
  • Διαβάστε επιστημονικές δημοσιεύσεις που σχετίζονται με την αναζήτησή σας
  • Αναζήτηση φαρμακευτικών βοτάνων με τα αποτελέσματά τους
  • Οργανώστε τα ενδιαφέροντά σας και μείνετε ενημερωμένοι με την έρευνα ειδήσεων, τις κλινικές δοκιμές και τα διπλώματα ευρεσιτεχνίας

Πληκτρολογήστε ένα σύμπτωμα ή μια ασθένεια και διαβάστε για βότανα που μπορεί να βοηθήσουν, πληκτρολογήστε ένα βότανο και δείτε ασθένειες και συμπτώματα κατά των οποίων χρησιμοποιείται.
* Όλες οι πληροφορίες βασίζονται σε δημοσιευμένη επιστημονική έρευνα

Google Play badgeApp Store badge